On 26/05/2011 9:13 a.m., Pete Ashdown wrote:
I'm having trouble figuring out how to hotswap dead drives on a potential
fileserver I am building. I'm using an LSI Internal SATA/SAS 9211-8i&
9211-4i to connect 12 SATA drives on a Supermicro backplane that supports
SES-2. I am finding conflicting information as to whether OpenIndiana can
light the bay LED of the failed drive on command. If it can, how do I do it?
If it can't, how do I identify which bay to swap the drive out of? Right now
I've got a mapping of drive serial #'s to bays, but that isn't ideal for a
group of admins to execute upon.
Also, although the backplane supports SES-2, I'm not seeing /dev/es/ses0. I
installed system/io/tests, but I don't have sestopo in that package.
The LSI SAS2 hba controllers don't seem to have ses2 support at present.
As far as I could tell, the ses functionality isn't present in the
firmware or drivers of the sas2 products.
see http://kb.lsi.com/KnowledgebaseArticle15874.aspx