Hi Sven,

thanks for your patch!

On Wed, Oct 24, 2018 at 4:25 PM Sven Van Asbroeck <sven...@arcx.com> wrote:

> +  - pwms : the pwm connected to the bridge's 'pwm input'.

That is really unintuitive and needs a detailed explanation. What
is a bridge doing with a PWM? Is it 100% certain this is a PWM,
it's not just a .... clock? A pwm is a pule WIDTH modulator and
I can't for my life understand why a bus bridge needs a signal
with variable pulse width, but surprise me! :D

> +               fsl,weim-cs-timing = <0x024400b1 0x00001010 0x20081100
> +                               0x00000000 0xa0000240 0x00000000>;

Is it just a copy/paste from
Documentation/devicetree/bindings/bus/imx-weim.txt
leftover?

It was mentioned as undocumented but it is also pretty terse
with these opaque hex numbers. I would never let the
Freescale binding pass if I was reviewing it.

Look at my bindings for Qualcomm EBI in
Documentation/devicetree/bindings/bus/qcom,ebi2.txt
for example.

But maybe it's not even supposed to be there.

Yours,
Linus Walleij