Thank-you thank-you. 20v works. Note to others: The Sipura seems to recognize the PSTN line status when it feels like it. I lowered to 20v and placed a test call which immediately worked. I then unplugged the KXT line from the Sipura and plugged it in again later and it didn't work. Powercycling the Sipura did the trick.
> "Note: A standard phone line puts out around -48v. The SPA-3000 detects > that a line is in use if the voltage drops below 30 (default setting). > However, our Panasonic only puts out -27v on the analog line (viewable > from the Info page). The SPA always thought the line was busy and wasn't > allowing me to make or receive calls. Dropped the in-use voltage to 20 > (something less than the on-hook voltage) and it worked." _________________________________________________________________ KX-T Mailing list --- http://kxthelp.com/ Subscription changes: http://kxthelp.com/mailman/listinfo/kxt