Github user fhueske commented on a diff in the pull request: https://github.com/apache/flink/pull/4373#discussion_r131094518 --- Diff: flink-libraries/flink-table/src/test/scala/org/apache/flink/table/api/stream/sql/JoinTest.scala --- @@ -55,12 +55,13 @@ class JoinTest extends TableTestBase { unaryNode( "DataStreamCalc", streamTableNode(1), - term("select", "a", "b", "proctime") + term("select", "a", "b", "-(proctime, 3600000) AS -", --- End diff -- Yes, you're of course right @twalthr. This is a valid rewrite and I agree with you're analysis. We have to prevent the push-down of predicates that include time indicator fields. The `DataStreamWindowJoin` needs the offsets to compute the correct window boundaries.
--- If your project is set up for it, you can reply to this email and have your reply appear on GitHub as well. If your project does not have this feature enabled and wishes so, or if the feature is enabled but not working, please contact infrastructure at infrastruct...@apache.org or file a JIRA ticket with INFRA. ---