> I did for SETSMS for COMMDS there was no response at all, but for SCDS and
> ACDS i got the below :
>
> setsms acds(system.zt01.acds)
> IGD068I ACDS SYSTEM.ZT01.ACDS SPECIFIED IS THE
> SAME AS THE ACTIVE ACDS - COMMAND IS REJECTED
>
>
> setsms scds(system.zt01.scds)
> IGD056I ACDS SYSTEM.ZT01.ACDS NOT FOUND
> IGD052I REQUEST DENIED - NO ACTIVE CONFIGURATION
>
It seems the ACDS doesn't exist or is not in that catalog. I usually have
trouble copying the COMMDS, so I just define a new one and use SETSMS
COMMDS(DFSMS.COMMDS) to start using it.
//DEFCOMDS EXEC PGM=IDCAMS
//SYSPRINT DD SYSOUT=*
//DD1 DD UNIT=SYSDA,
// VOL=SER=Z13RS2,
// DISP=OLD
//SYSIN DD *
DELETE (DFSMS.COMMDS) CLUSTER PURGE +
FILE(DD1) +
CATALOG(CATALOG.MVSICFM.VZ13RS2)
DEFINE CLUSTER( +
NAME(DFSMS.COMMDS) +
LINEAR +
VOLUME(Z13RS2) +
TRK(2,1) +
SHAREOPTIONS(2,3) ) +
DATA( +
NAME(DFSMS.COMMDS.DATA)) +
CATALOG(CATALOG.MVSICFM.VZ13RS2)
/*
Cliff McNeill
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN