You got that error with the &1 and &2? That's not right either...!

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
salva
Sent: Thursday, September 11, 2025 10:28 AM
To: [email protected]
Subject: Re: Would you consider this a compiler bug?

I tried it and obtained an:

IGYCB7149-S An error opening "&1" was detected in "CDA" phase at &2.

So it must be a ptf level issue.

Curiously, the mdeck is on the spool!


El jue, 11 sept 2025, 16:05, Phil Smith III <[email protected]> escribió:

> Yes, I know that. Sorry, not sure what your point is? The real 
> question is whether this should be considered a compiler bug or not. I 
> don't think I should be able to cause an "internal error" like that.
>
> -----Original Message-----
> From: IBM Mainframe Discussion List <[email protected]> On 
> Behalf Of Sri Hari Kolusu
> Sent: Thursday, September 11, 2025 9:32 AM
> To: [email protected]
> Subject: Re: Would you consider this a compiler bug?
>
> > Changing that to
> //SYSMDECK DD UNIT=SYSDA,SPACE=(CYL,(1,1)) made it happy.
>
> Phil,
>
> The SYSMDECK dataset need to a permanent MVS dataset which is 
> documented here
>
>
> https://www.ibm.com/docs/en/cobol-zos/6.5.0?topic=output-defining-libr
> ary-processing-file-sysmdeck
>
> As peter mentioned " You should look at the delivered sample PROC's in 
> <hlq>.SIGYPROC to help you configure your local compile procedure.  
> You would have seen the correct SYSMDECK DD specification there."
>
> You would have found the supplied procedures have the following
>
> //SYSMDECK DD  UNIT=SYSALLDA,SPACE=(CYL,(1,1)),VOL=(,,,1)
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions, send 
> email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to