On Mon, 20 Jan 2025 09:42:15 -0500, Phil Smith III wrote:

>MODE B and TYPE E are not universal, alas.
> 
From a desktop I've tried:
    BINARY
    QUOTE SITE STRU R
(The desktop didn't accept STRU.)  For  successful round-trip binary VB data.
Alas, it failed for RECFM VBS, treating each segment as an entire record.
I suspect STRU R has no representation of an incomplete record.


>On 19/01/2025 6:00 am, Kirk Wolf wrote:
>> I'm 99% certain that there are some "site" options in IBM FTP that will 
>> round-trip binary VB data.    I've seen it discussed on IBM-MAIN, but not 
>> for years and I can't recall the details.

-- 
gil

----------------------------------------------------------------------