> -----Original Message-----
> From: IBM Mainframe Discussion List On Behalf Of Hilario G.
> 
> Hi,
> 
> I have an extrange problem for mi. On the member  IEASYSxx y have a
sentence for
> the LPALST library concatenations (LPA=xx).
> 
> I discovered that the SVC for CICS when I start CICS isssue a problem
that
> couldn't found the SVC 216.
> 
> I follow the SYSLOG and not appear any sentence that the system use
the
> LPAxx that I put on IEASYSxx.

Did you IPL with CLPA=YES?

    -jc-

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html