Forgive me for asking the simple question first - After you updated 
PARMLIB to modify the contents of the LPA, did you remember to IPL with 
CLPA?

===============================================
Wayne Driscoll
OMEGAMON DB2 L3 Support/Development
wdrisco(AT)us.ibm.com
===============================================



From:
"Hilario G." <[email protected]>
To:
[email protected]
Date:
05/03/2011 02:18 AM
Subject:
Problem with LPA=xx on IEASYSxx
Sent by:
IBM Mainframe Discussion List <[email protected]>



Hi,

I have an extrange problem for mi. On the member  IEASYSxx y have a 
sentence for
the LPALST library concatenations (LPA=xx).

I discovered that the SVC for CICS when I start CICS isssue a problem that
couldn't found the SVC 216.

I follow the SYSLOG and not appear any sentence that the system use the
LPAxx that I put on IEASYSxx.

I appreciate any suggestions.

Kind Regards.

Hilario.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html



----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html