The SMF30 record is completed with data from other records, eg. SMF4(step 
termination).  
It's possible that the date/time is maintained elsewhere until such time that 
the SMF30 needs to be written.  

There are fields SMF4SIT/SMF4SITD for "initiator selected this step".  


 
> Date: Thu, 2 Dec 2010 22:48:28 +0000
> From: [email protected]
> Subject: Re: Field that contains timestamp of when current jobstep started?
> To: [email protected]
> 
> >I know. But no date field that I can find.
> 
> There has to be.
> The SMF30 records have an 8 byte field that has date and time.
> It has to come from somewhere.
> 
> -
> Ted MacNEIL
> [email protected]
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: GET IBM-MAIN INFO
> Search the archives at http://bama.ua.edu/archives/ibm-main.html
                                          
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html