In <[email protected]>, on
11/26/2010
   at 02:17 PM, Tony Harminc <[email protected]> said:

>As I said, IBM is inconsistent with its terminology. The TSO/E REXX
>Users Guide, and the corresponding REXX Reference, define and use the
>term "Host Command Environment". But the control blocks refer to
>"subcommands", which is probably a legacy from REXX's CMS roots, and
>as you say, MFC uses "external environment".

Which still leaves unexplained your response in
<[email protected]>:

     I think you are confusing REXX environments with
     REXX Host Command Environments.

It is normal to  invoke a REXX script with multiple external
environments available, e.g., for ISPF/PDF EDIT macros. There is no
reason that TSO services would not be available.
 
-- 
     Shmuel (Seymour J.) Metz, SysProg and JOAT
     ISO position; see <http://patriot.net/~shmuel/resume/brief.html> 
We don't care. We don't have to care, we're Congress.
(S877: The Shut up and Eat Your spam act of 2003)

----------------------------------------------------------------------