Dear Freesurfer Experts,

I’m evaluating WMH-SynthSeg for white matter lesion segmentation using the most 
recent development version, and ran into similar issues reported last month: 
https://secure-web.cisco.com/15YjRoSDCoF2Q2A8SbHg4Jal044A5FQlCGhkswUXxVl-RCU42MnhOnROjNeQ0N8aY1j5q-c0EIZxuvWi9b2BY3_RcavrvdsqyUMxh0pJBCvdkvBk9heTacObFxDABUoLfQoYBCuo8MRJ1klcb2u-ZgeCAQZTNFG_VGq2v37dfIRoJlZvFB1c7q3NxokKuuopV7jXHQBzMClEUl8L-3SbglD9DmdXGhFbM9SoKFLSNoyBtgr7QewklOtqD6BFOeQLd1Yxc5SC-8_y9q_bmcb-bfcd6vKxUshHlcYcK1lJRasJnuos-8ajTKLn85B1QuYJvSGfzPXXsqLcOepc8n_u7ZA/https%3A%2F%2Fwww.mail-archive.com%2Ffreesurfer%40nmr.mgh.harvard.edu%2Fmsg76177.html

I was running this as CPU only on a Mac Studio (M2 Ultra) with 192GB RAM. I 
tried is multiple times with 1-8 threads, and the process was killed in each 
instance. Viewing memory usage through the Mac OS Activity Monitor while 
running WMH-Synthseg, it appears that memory usage ramps up to >200GB (at which 
time the process is killed). With system resources consuming ~10GB RAM, it 
seems there should still be sufficient memory if it only requires ~32GB RAM. 
Are there any other (i.e., non-documented) options for running the process on 
CPU only? Any other suggestions are greatly appreciated.

Regardless of specific suggestions you may have, I wanted to bring this to your 
attention as a potential bug that could produce memory leaks or similar issues.

Thanks,
Drew


Andrew R. Bender, Ph.D.  |   Staff Neuroimaging Research
Cleveland Clinic Lou Ruvo Center for Brain Health


Please consider the environment before printing this e-mail

Cleveland Clinic is a nonprofit, multispecialty academic medical center that's 
recognized in the U.S. and throughout the world for its expertise and care. 
Visit us online at 
http://secure-web.cisco.com/1OkDITwicfyyjVUCL08BSHJwZJEGdzrgLwoI3jy6-6mImmCIyHQAwixR1nmYrIZ1AHVak2GSlBvEWGLW5vebQJWeejfibfG1mMCIOeWb4kDdYH6Sp3VVfHOuSpku3k9F6OUW3E22_nZoy4uaQRVlldmb-XHDPb3_yGvuvHAGdlwswsMeilBdw0eJvqTbrJqNdtI_xVypye54XImP7yMuwVE7M61KU5e7C_-8sQRKYGU-GA-ftOxTOnc9MCeE-3Jd2sDc_i86Hn8jHjznrahJwM-a7TEv02kDt-Tt1yVaqksCt-S-4GlCfY6Nf2PU7yAp5wSPZVKjUGKJ-KglAuMu6Gw/http%3A%2F%2Fwww.clevelandclinic.org
 for a complete listing of our services, staff and locations. Confidentiality 
Note: This message is intended for use only by the individual or entity to 
which it is addressed and may contain information that is privileged, 
confidential, and exempt from disclosure under applicable law. If the reader of 
this message is not the intended recipient or the employee or agent responsible 
for delivering the message to the intended recipient, you are hereby notified 
that any dissemination, distribution or copying of this communication is 
strictly prohibited. If you have received this communication in error, please 
contact the sender immediately and destroy the material in its entirety, 
whether electronic or hard copy. Thank you.
_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer
The information in this e-mail is intended only for the person to whom it is 
addressed.  If you believe this e-mail was sent to you in error and the e-mail 
contains patient information, please contact the Mass General Brigham 
Compliance HelpLine at https://www.massgeneralbrigham.org/complianceline 
<https://www.massgeneralbrigham.org/complianceline> .
Please note that this e-mail is not secure (encrypted).  If you do not wish to 
continue communication over unencrypted e-mail, please notify the sender of 
this message immediately.  Continuing to send or respond to e-mail after 
receiving this message means you understand and accept this risk and wish to 
continue to communicate over unencrypted e-mail. 

Reply via email to