External Email - Use Caution Hi there,
I want to map the intensities of the fMRI 4D volumes onto its surface in order to get the functional values on each vertex in each frame. I have done the following steps for achieving this: 1. ran recon-all on its anatomical volume. 2. register the fMRI series with the anatomical volume by using bbregister. 3. assign values from volumes to each surface vertex through the command mri_vol2surf. I have got a result of mapping the 4D volumes intensities onto its surfaces but there are 35.5% vertices assigned 0 value in every time frame. I am wondering is the ratio reasonable and how could I improve the result? I guess resolution would be one of reasons causing the high 0 value ratio, my fMRI data is 2mm^3 and anatomical data is 1mm^3. Many thanks for your help. Best, An
_______________________________________________ Freesurfer mailing list Freesurfer@nmr.mgh.harvard.edu https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer