External Email - Use Caution        

Hey

So opening only the conformed image in freeview, mricro and fsleyes constantly 
gives me crazy results. Also, the wm segmentation is completely wrong so I 
really think there something wrong in the file….

Best

Antonin

Hôpital Erasme - ULB
Cliniques universitaires de Bruxelles
Route de Lennik 808 - B - 1070 Bruxelles
S www.erasme.ulb.ac.be

Disclaimer : http://www.erasme.ulb.ac.be/email-disclaimer

> On 3 Sep 2019, at 15:55, Bruce Fischl <fis...@nmr.mgh.harvard.edu> wrote:
>
> Hi Antonin
>
> hmmm. Can you try *only* loading the conformed image and seeing how it looks? 
> freeview will use one of the images as the basis for it's display 
> coordinates, which can cause apparent slicing artifacts that are only display 
> issues for other volumes.
>
> cheers
> Bruce
>
> On Tue, 3 Sep 2019, Rovai Antonin wrote:
>
>>         External Email - Use Caution
>> Hello again
>> I have the following issue when running mri_convert. When using the option
>> -conform option (as in the reconall pipeline), the sag slices seems to be
>> shifted at some point (see attached pictures). What is happening?
>> By the way the option description is not super clear, could you please give
>> some extra details?
>> Best
>> Antonin
>> [IMAGE][IMAGE]
>> Hôpital Erasme
>> Lien vers Disclaimer
> _______________________________________________
> Freesurfer mailing list
> Freesurfer@nmr.mgh.harvard.edu
> https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer

Reply via email to