Hi,
Talairach.xfm is a text file which contains a transformation matrix. Though there is small numerical difference between two transformation matrix made using mritotal and the default Talairach registration. The process of calculation the ICV may amplify this difference since it used the determinate of the transformation matrix to calculate ICV. The differences in ICV may depend on how different the numerical values of the Talairach transformation matrix are.

Best regrards
Knut J

On 12/14/2012 09:06 PM, Eric Cunningham wrote:
Hi,

this link:
http://surfer.nmr.mgh.harvard.edu/fswiki/TalFailV5.1
discusses a solution to bad talairach.xfm transforms, the -use-mritotal flag.

this link:
http://surfer.nmr.mgh.harvard.edu/fswiki/eTIV
mentions that the talairach.xfm is used to calculate the total intracranial volume.

is using mritotal likely to result in significantly different intracranial volumes even if the talairach.xfm does not appear to be very different when viewed?

thanks much,
-eric




_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.

_______________________________________________
Freesurfer mailing list
Freesurfer@nmr.mgh.harvard.edu
https://mail.nmr.mgh.harvard.edu/mailman/listinfo/freesurfer


The information in this e-mail is intended only for the person to whom it is
addressed. If you believe this e-mail was sent to you in error and the e-mail
contains patient information, please contact the Partners Compliance HelpLine at
http://www.partners.org/complianceline . If the e-mail was sent to you in error
but does not contain patient information, please contact the sender and properly
dispose of the e-mail.

Reply via email to