> Hello,
> 
> We are having some trouble with autorecon1, specifially the watershed step.
> Here's the error we get:
> 
> 
> > #--------------------------------------------
> > [EMAIL PROTECTED] Skull Stripping Tue Nov 18 15:19:59 EST 2008
> > /autofs/space/madrc_007/users/adeluca/RETRRO_structural/RETRRO_20_old/mri
> >
> > mri_watershed -T1 -brain_atlas 
> > /usr/local/freesurfer/stable4/average/RB_all_withskull_2008-03-26.gca 
> > transforms/talairach_with_skull.lta T1.mgz brainmask.auto.mgz
> >
> >
> > Mode:          T1 normalized volume
> > Mode:          Use the information of atlas (default parms, --help for 
> > details)
> >
> > *********************************************************
> > The input file is T1.mgz
> > The output file is brainmask.auto.mgz
> > If this is incorrect, please exit with CTL-C
> >
> > Weighting the input with atlas information before watershed
> >
> > *************************WATERSHED**************************
> > Sorting...
> >      first estimation of the COG coord: x=128 y=108 z=113 r=76
> >      first estimation of the main basin volume: 1871279 voxels
> >
> >
> >
> > *******************************************
> > ***********************************************
> > ***********************************************
> > White matter intensity 0 is lower than CSF intensity 18.
> > Please examine input images.  Will terminate ...
> > ***********************************************
> > ***********************************************
> > ***********************************************
> >
> > **********************************************************
> >         MRIstripSkull failed.
> > ************************************************************
> > Linux aubz 2.6.18-92.1.10.el5 #1 SMP Tue Aug 5 07:42:41 EDT 2008 x86_64 
> > x86_64 x86_64 GNU/Linux
> >
> > recon-all exited with ERRORS at Tue Nov 18 15:20:09 EST 2008
> 
> 
> Looking at the input file (nu.mgz) it is obvious that the qcquired image isn't
> as good as it could be. Looks like there is moderate white matter burden,
> dropout on the ventral side of the scan, and some artifacts possibly made
> because of dental implants.
> 
> Are there any other steps that can be taken besides marking control points and
> adding the -f flag to mri_normalize?
> 
> Thanks,
> Jon
> 
> 