A personal history, as intern/coop student, circa 1980-81, I was tasked with 
trying to capture the cap voltage just after disconnect.  Because a consumer 
complained about getting shocked.  Engineers general thoughts were it decays 
fast enough to not be a problem, and that ought teach the consumer to not touch 
the plug pins.Well I got the job of providing evidence.So setup scopes and a 
stock of polaroid film (only way for screen captures), after some time plugging 
and unplugging subject equipment, the high voltage and decay time were 
recorded.Consumer indeed could get shocked.Internal corp redesigned all 
pluggable power supplies to decay at an arbitrary rate influenced by safety 
opinions.And data went to committees for additional debates.  And here we are 
!!!

Sent from Yahoo Mail on Android 
 
  On Mon, Oct 17, 2022 at 18:01, Richard Nute<[email protected]> wrote:   
#yiv7518696537 #yiv7518696537 -- _filtered {} _filtered {}#yiv7518696537 
#yiv7518696537 p.yiv7518696537MsoNormal, #yiv7518696537 
li.yiv7518696537MsoNormal, #yiv7518696537 div.yiv7518696537MsoNormal 
{margin:0in;font-size:11.0pt;font-family:sans-serif;}#yiv7518696537 
span.yiv7518696537EmailStyle18 {font-family:New 
serif;color:windowtext;}#yiv7518696537 .yiv7518696537MsoChpDefault 
{font-size:10.0pt;font-family:sans-serif;} _filtered {}#yiv7518696537 
div.yiv7518696537WordSection1 {}#yiv7518696537 
 

  

See attached for a comprehensive discussion of X and Y capacitor discharge 
measurement techniques.

  

In some standards, the use of a 100-megohm probe is accepted without correction 
for its resistance.  

  

Best regards,

Rich

IEEE Life Fellow

IEEE Medal for Environmental and Safety Technologies

  

  

  

  
-
----------------------------------------------------------------

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web 
at:http://www.ieee-pses.org/emc-pstc.html

Website: http://www.ieee-pses.org/
Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]>

 To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC&A=1 
  

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>
_________________________________________________
To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC&A=1

Reply via email to