On Wed, Sep 17, 2008 at 09:52:32AM -0700, Bruce Korb wrote: > It also turns out that to correctly read drive temperature, you need to > set the ``-R 194'' option in the config file. RE: > http://defindit.com/readme_files/smartd_smartctl.html > > > Problem: > > For attribute 194 (Temperature_Celsius), smartd currently > > detects differences of the VALUE and WORST columns, where > > it should instead pay attention to RAW_VALUE for the drive > > temperature. > > > > Resolution (from web): > > The solution is to change the drive specifier lines in > > /etc/smartd.conf. This hint is from a web page and from > > the man page "man smartd.conf". The appropriate lines from > > /ect/smartd.conf read: > > > > /dev/hda -a -R 194 > > /dev/sda -a -d ata -R 194 > > Unfortunately, you have to upgrade to 5.39 to parse that option. > Please? Thank you. There is no 5.39 relese. -- Guido
-- To UNSUBSCRIBE, email to [EMAIL PROTECTED] with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]