Dennis had a good call with heat shrink and painting with liquid electrical tape. I took made my heat shrink about two inches longer than the connection, and injected marine silicone inside with a syringe. When the shrunk, silicone gushed out the ends. It has been wet often.

Maybe I'm just lucky, but my 12 year old Rule pumps and float switches are still doing fine. I have a little 500 as the primary pump, and a big one that stays up on a platform about six inches off the bilge, just in case. The 500 does get clogged up with bilge gunk, and I just replaced it because they can't be taken apart and cleaned out. One thing I do is take a garden hose to 3/4" adapter and flush the hose out with high pressure dock water. I'll also backflush the pump with the garden hose.

Most of the float switches I've seen fail are really due to bad wiring. I've seen plain crimp connections just sitting in the bilge, and it's no wonder the wire rots out. The worst, if you can believe it, was just wires twisted together and covered with electrical tape. No kidding. I found that down here in Mexico, as the sport fishing boat was sinking at the dock. The guy came back to town, and when I told him that I'd saved his boat he didn't even say thanks. Power boaters. (It probably didn't help that I said whoever did the wiring ought to be taken out and shot.)

Wal



you CnC-List wrote:
I ran a rule float switch to one which failed that first year.


_______________________________________________
This List is provided by the C&C Photo Album

Email address:
CnC-List@cnc-list.com
To change your list preferences, including unsubscribing -- go bottom of page 
at:
http://cnc-list.com/mailman/listinfo/cnc-list_cnc-list.com

Reply via email to