Hi Dimitry,

removing of the other cards did not help. The chassis still boots into PFC3 mode.

7606S-lab#show platform hardware pfc mode
PFC operating mode : PFC3C

7606S-lab#
7606S-lab#show module
Mod Ports Card Type Model Serial No. --- ----- -------------------------------------- ------------------ ----------- 4 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL16020J6H 6 2 Route Switch Processor 720 (Active) RSP720-3CXL-GE SAL1538QMQX

Mod MAC addresses Hw Fw Sw Status --- ---------------------------------- ------ ------------ ------------ -------
  4  0011.204f.ff68 to 0011.204f.ff6b   1.5   12.2(18r)S1  12.2(33)SRE1 Ok
  6  001c.584c.ab98 to 001c.584c.ab9b   5.9   12.2(33r)SRE 12.2(33)SRE1 Ok

Mod Sub-Module Model Serial Hw Status ---- --------------------------- ------------------ ----------- ------- -------
  4  Distributed Forwarding Card WS-F6700-DFC3CXL   SAL1406AMHG  1.4    Ok
  6  Policy Feature Card 3       7600-PFC3CXL       SAL153813DT  1.0    Ok
  6  C7600 MSFC4 Daughterboard   7600-MSFC4         SAL1538AW19  1.5    Ok


7606S-lab#show platform hardware pfc mode
PFC operating mode : PFC3C


*Feb 25 05:59:37.027: %OIR-SP-6-DOWNGRADE_EARL: Module 6 PFC installed is not identical to system PFC and will perform at current system operating mode.


I think it could not have helped at all. I am sure mixing of DFC (same version of PFC) and CFC enabled linecards works.

We have in production other 7606S boxes, with a mix of CFC and DFC cards and it RUNS in PFC3CXL.

For example this chassis ->

TTC.Core.7606#show module
Mod Ports Card Type Model Serial No. --- ----- -------------------------------------- ------------------ ----------- 1 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL17236EGR 2 8 CEF720 8 port 10GE with DFC WS-X6708-10GE SAL1221R8JP 3 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL1031X086 4 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL1033YKZ4 5 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX SAL10019PF0 6 2 Route Switch Processor 720 (Active) RSP720-3CXL-GE JAE1127P1GQ

Mod MAC addresses Hw Fw Sw Status --- ---------------------------------- ------ ------------ ------------ -------
  1  10f3.11b9.4684 to 10f3.11b9.4687   3.3   12.2(14r)S5  12.2(33)SRE7 Ok
  2  001e.f7f7.bd58 to 001e.f7f7.bd5f   1.4   12.2(18r)S1  12.2(33)SRE7 Ok
  3  000a.b882.eeac to 000a.b882.eeaf   2.4   12.2(14r)S5  12.2(33)SRE7 Ok
  4  000a.b8a6.6130 to 000a.b8a6.6133   2.4   12.2(14r)S5  12.2(33)SRE7 Ok
  5  0016.9dcb.5de8 to 0016.9dcb.5e17   2.9   12.2(14r)S5  12.2(33)SRE7 Ok
  6  001b.d401.5250 to 001b.d401.5253   5.2   12.2(33r)SRB 12.2(33)SRE7 Ok

Mod Sub-Module Model Serial Hw Status ---- --------------------------- ------------------ ----------- ------- -------
  1  Distributed Forwarding Card WS-F6700-DFC3CXL   SAL114350GM  1.0    Ok
  2  Distributed Forwarding Card WS-F6700-DFC3CXL   SAL1218P9M9  1.1    Ok
  3  Distributed Forwarding Card WS-F6700-DFC3CXL   SAL1417G6U4  1.6    Ok
  4  Centralized Forwarding Card WS-F6700-CFC       SAL1032XFKL  2.0    Ok
  5  Centralized Forwarding Card WS-F6700-CFC       SAL1333WM1T  4.1    Ok
  6  Policy Feature Card 3       7600-PFC3CXL       JAE1127P6R8  1.0    Ok
  6  C7600 MSFC4 Daughterboard   7600-MSFC4         JAE1127PBGQ  1.1    Ok


TTC.Core.7606#show platform hardware pfc mode
PFC operating mode : PFC3CXL



So the setup is almost the same as the chassis in subject.


Jiri

Dne 30.7.2014 14:47, Dimitris Befas napsal(a):
Hi Jiri,

Remove the cfc modules from the chassis. No matter if they are admin shut.

On Jul 30, 2014 1:35 PM, "Jiri Prochazka"
<[email protected] <mailto:[email protected]>>
wrote:

    Hi,

    I am afraid this would not help. I am aware of two CFC modules on
    two linecards, but as you can see, all cards except RSP720 and one
    6704 are powered down (manually).

    Even if they would not be, the chassis should operate in 3CLX mode,
    not 3C. 3CXL is the lowest demoninator of DFC's in the chassis.

    Jiri

    On July 30, 2014 12:13:50 PM CEST, Dimitris Befas
    <[email protected] <mailto:[email protected]>> wrote:

        You cannot get an PFC3CXL mode when combining CFC and PFC
        sub-modules. The PFC capability is per module, but the PFC mode
        is a chassis function.

        For your specific hardware config, you will accomplish a PFC3CXL
        mode only if you remove slots 3 and 5 or if you replace their
        sub-modules with DFC3CXL.

        Dimitris

        On Jul 30, 2014 12:39 PM, "Jiri Prochazka"
        <[email protected]
        <mailto:[email protected]>> wrote:

            Hi,

            I am building a new 7606S chassis, with RSP720-3CXL
            (12.2(33)SRE10) and a few X6704-10GE linecards.

            Most of 6704-10GE cards are equipped with DFC3C-XL modules.

            The problem is that two DFC3C-XL modules are unwilling to
            operate in 3C-XL mode. Both DFC's are from different
            sources, so I highly doubt both are faulty the same way.

            But both show the same symptoms. Although they are 3C-XL
            versions, they work as 3C only..which degrades PFC operating
            mode of the whole chassis to PFC3C. As soon as I swap DFC on
            respective 6704 card to some other piece, it works OK.

            What confuses me the most is this log record ->

            *Feb 25 02:15:11.324: %OIR-SP-6-DOWNGRADE_EARL: Module 6 PFC
            installed is not identical to system PFC and will perform at
            current system operating mode.


            WS-X6704-10GE with WS-F6700-DFC3CXL is in the SLOT 4.
            RSP720-3CXL-GE with 7600-PFC3CXL is in the SLOT 6.

            Why is the switch complaining that PFC in slot6 (Supervisor)
            is not identical to system PFC (Supervisor?)?


            7606S-lab#show module
            Mod Ports Card Type                              Model
            Serial No.
            --- ----- ------------------------------__--------
            ------------------ -----------
               1    4  CEF720 4 port 10-Gigabit Ethernet
              WS-X6704-10GE SAL1552ZWUQ
               2    4  CEF720 4 port 10-Gigabit Ethernet
              WS-X6704-10GE SAL1545UJY7
               3    4  CEF720 4 port 10-Gigabit Ethernet
              WS-X6704-10GE SAL1234173T
               4    4  CEF720 4 port 10-Gigabit Ethernet
              WS-X6704-10GE SAL16020J6H
               5   48  CEF720 48 port 10/100/1000mb Ethernet
              WS-X6748-GE-TX SAL10019Q21
               6    2  Route Switch Processor 720 (Active)
              RSP720-3CXL-GE SAL1538QMQX

            Mod MAC addresses                       Hw    Fw
            Sw Status
            --- ------------------------------__---- ------ ------------
            ------------ -------
               1  0011.934a.001c to 0011.934a.001f   1.5   Unknown
              Unknown  PwrDown
               2  0011.9370.270c to 0011.9370.270f   1.5   Unknown
              Unknown  PwrDown
               3  0022.902b.fc44 to 0022.902b.fc47   2.7   Unknown
              Unknown  PwrDown
               4  0011.204f.ff68 to 0011.204f.ff6b   1.5   12.2(18r)S1
              12.2(33)SRE1 Ok
               5  0016.9dcb.6434 to 0016.9dcb.6463   2.9   Unknown
              Unknown  PwrDown
               6  001c.584c.ab98 to 001c.584c.ab9b   5.9   12.2(33r)SRE
            12.2(33)SRE1 Ok

            Mod  Sub-Module                  Model              Serial
                 Hw Status
            ---- --------------------------- ------------------
            ----------- ------- -------
               1  Distributed Forwarding Card WS-F6700-DFC3CXL
            SAL1423K3UR  1.6  PwrDown
               2  Distributed Forwarding Card WS-F6700-DFC3CXL
            SAL160101ZB  1.7  PwrDown
               3  Centralized Forwarding Card WS-F6700-CFC
            SAL12330HQ6  4.1  PwrDown
               4  Distributed Forwarding Card WS-F6700-DFC3CXL
            SAL1406AMHG  1.4    Ok
               5  Centralized Forwarding Card WS-F6700-CFC
            SAL1336XWTP  4.1  PwrDown
               6  Policy Feature Card 3       7600-PFC3CXL
            SAL153813DT  1.0    Ok
               6  C7600 MSFC4 Daughterboard   7600-MSFC4
            SAL1538AW19  1.5    Ok


            After a reload with card inserted and powered, the chassis
            loads to PFC3 mode.

            7606S-lab#show platform hardware pfc mode
            PFC operating mode : PFC3C

            As soon as I remove the card, reload, the chassis loads to
            PFC3C-XL mode. When the card is inserted, it's powered down,
            to prevent DFC mismatch. Even when the DFC and PFC version
            is the same..both XL.


            Any thoughts what can be wrong? Other than 'two faulty DFC
            modules'. As I said, both are from different sources and we
            have used both previously so it's really unlikely.


            Thanks!


            Jiri







            _________________________________________________
            cisco-nsp mailing list [email protected]
            <mailto:[email protected]>
            https://puck.nether.net/__mailman/listinfo/cisco-nsp
            <https://puck.nether.net/mailman/listinfo/cisco-nsp>
            archive at http://puck.nether.net/__pipermail/cisco-nsp/
            <http://puck.nether.net/pipermail/cisco-nsp/>


    --
    Sent from my Android device with K-9 Mail. Please excuse my brevity.


--
Jiri Prochazka
network administrator (AS39392)
SuperNetwork s.r.o.

m: +420 777 87 37 67
w: http://www.superhosting.cz
e: [email protected]
_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to