Hi,

I am building a new 7606S chassis, with RSP720-3CXL (12.2(33)SRE10) and a few X6704-10GE linecards.

Most of 6704-10GE cards are equipped with DFC3C-XL modules.

The problem is that two DFC3C-XL modules are unwilling to operate in 3C-XL mode. Both DFC's are from different sources, so I highly doubt both are faulty the same way.

But both show the same symptoms. Although they are 3C-XL versions, they work as 3C only..which degrades PFC operating mode of the whole chassis to PFC3C. As soon as I swap DFC on respective 6704 card to some other piece, it works OK.

What confuses me the most is this log record ->

*Feb 25 02:15:11.324: %OIR-SP-6-DOWNGRADE_EARL: Module 6 PFC installed is not identical to system PFC and will perform at current system operating mode.


WS-X6704-10GE with WS-F6700-DFC3CXL is in the SLOT 4. RSP720-3CXL-GE with 7600-PFC3CXL is in the SLOT 6.

Why is the switch complaining that PFC in slot6 (Supervisor) is not identical to system PFC (Supervisor?)?


7606S-lab#show module
Mod Ports Card Type Model Serial No. --- ----- -------------------------------------- ------------------ ----------- 1 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL1552ZWUQ 2 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL1545UJY7 3 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL1234173T 4 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL16020J6H 5 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX SAL10019Q21 6 2 Route Switch Processor 720 (Active) RSP720-3CXL-GE SAL1538QMQX

Mod MAC addresses Hw Fw Sw Status --- ---------------------------------- ------ ------------ ------------ ------- 1 0011.934a.001c to 0011.934a.001f 1.5 Unknown Unknown PwrDown 2 0011.9370.270c to 0011.9370.270f 1.5 Unknown Unknown PwrDown 3 0022.902b.fc44 to 0022.902b.fc47 2.7 Unknown Unknown PwrDown
  4  0011.204f.ff68 to 0011.204f.ff6b   1.5   12.2(18r)S1  12.2(33)SRE1 Ok
5 0016.9dcb.6434 to 0016.9dcb.6463 2.9 Unknown Unknown PwrDown
  6  001c.584c.ab98 to 001c.584c.ab9b   5.9   12.2(33r)SRE 12.2(33)SRE1 Ok

Mod Sub-Module Model Serial Hw Status ---- --------------------------- ------------------ ----------- ------- ------- 1 Distributed Forwarding Card WS-F6700-DFC3CXL SAL1423K3UR 1.6 PwrDown 2 Distributed Forwarding Card WS-F6700-DFC3CXL SAL160101ZB 1.7 PwrDown 3 Centralized Forwarding Card WS-F6700-CFC SAL12330HQ6 4.1 PwrDown
  4  Distributed Forwarding Card WS-F6700-DFC3CXL   SAL1406AMHG  1.4    Ok
5 Centralized Forwarding Card WS-F6700-CFC SAL1336XWTP 4.1 PwrDown
  6  Policy Feature Card 3       7600-PFC3CXL       SAL153813DT  1.0    Ok
  6  C7600 MSFC4 Daughterboard   7600-MSFC4         SAL1538AW19  1.5    Ok


After a reload with card inserted and powered, the chassis loads to PFC3 mode.

7606S-lab#show platform hardware pfc mode
PFC operating mode : PFC3C

As soon as I remove the card, reload, the chassis loads to PFC3C-XL mode. When the card is inserted, it's powered down, to prevent DFC mismatch. Even when the DFC and PFC version is the same..both XL.


Any thoughts what can be wrong? Other than 'two faulty DFC modules'. As I said, both are from different sources and we have used both previously so it's really unlikely.


Thanks!


Jiri