On Nov 29, 2013, at 6:09 PM, Nikolay Shopik <[email protected]> wrote:
> Even when you draw graph in 5 min interval? Yes. Your graphs will be way off unless you bring the active timer down to 60s, irrespective of graph resolution. You should also consider graphing with 1-minute intervals, it's more operationally useful. > As lowering values means more flows exported per min so more load. NDE is going to consume a very low CPU percentage, normally single-digit; if you're so close to the edge that NDE load matters, you have bigger problems. ;> ----------------------------------------------------------------------- Roland Dobbins <[email protected]> // <http://www.arbornetworks.com> Luck is the residue of opportunity and design. -- John Milton _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/