On 29/11/13 14:59, Dobbins, Roland wrote:
> Any NetFlow, sampled or non-sampled.
> 
> Set the active timer to 60s, and the inactive timer to 5s.

Even when you draw graph in 5 min interval? As lowering values means
more flows exported per min so more load.

> 
>> > c7201(config-if)#ip flow monitor IPv4 sampler SM input
>> >                                              ^
>> > % Invalid input detected at '^' marker.
> Try this:
> 
> c7201(config-if)#ip flow monitor IPv4 sampler ?
> 
> or
> 
> c7201(config-if)#ip flow monitor IPv4 ?
> 
> and see what options it gives.

c7201(config-if)#ip flow monitor IPv4 ?
  input      Apply Flow Monitor on input traffic
  multicast  Apply Flow Monitor on multicast traffic
  output     Apply Flow Monitor on output traffic
  sampler    Optional Sampler to apply to this Flow Monitor
  unicast    Apply Flow Monitor on unicast traffic

c7201(config-if)#ipv6 flow monitor IPv4 sampler ?
% Unrecognized command

Even tried just "ip flow monitor IPv4 sampler" still Unrecognized command
_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp