Hmmm -are the two ano maps contoured at the same level? You can check this by setting the SCROLL option to the ano map.
The 2mFo-DFc maps look pretty identical..which suggests the two input mtz files are similar. You can get more information by viewing the inputs to make sure the values are the same.. Eleanor On Wed, 2 Aug 2023 at 13:53, Andrea Smith <andrea.sm...@uochb.cas.cz> wrote: > Dear all, > > I used refmac in CCP4Cloud and then I opened the generated .pdb and .mtz > from the CCP4Cloud job both in Linux Coot 0.9.6. and WinCoot 0.9.6. I can > see different anomalous maps in Coot and Wincoot - see attached printscreen > where on the left there is a green electron density between the aspartates > while on the right there is none. I tried to search if this is a bug but > couldn't find info about this. > > Am I doing something wrong? Do I have a local software issue? > > Any advice would be appreciated, best, > Andrea > > ------------------------------ > > To unsubscribe from the CCP4BB list, click the following link: > https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1 > ######################################################################## To unsubscribe from the CCP4BB list, click the following link: https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1 This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a mailing list hosted by www.jiscmail.ac.uk, terms & conditions are available at https://www.jiscmail.ac.uk/policyandsecurity/