Hardly enough information!
Resolution?

Wrong spacegroup - eg P21212 when it should be P212121 or something?

Wrong estimate of model difference? That can afffect LLG quite a lot?

 But there are many reasons..
Does the Rfactor fall when you refine? A change of R=55% to R=47% usually
indicates the solution is somewhat correct and can be improved..


On Mon, 10 Jun 2019 at 12:37, Weixi Gu <weixi...@uq.net.au> wrote:

> Dear all,
> I have been using Phaser for molecular replacement. One of the search
> models I tired generated 5 MR solutions. The best solution has a over 300
> LLG value, but a low TFZ value (5). I checked the map in coot. The density
> and model didn't match well. I am wondering if it is normal? What's the
> problem?
> Thank you!
> Cheers,
> Weixi
>
> ------------------------------
>
> To unsubscribe from the CCP4BB list, click the following link:
> https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCP4BB&A=1
>

########################################################################

To unsubscribe from the CCP4BB list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCP4BB&A=1

Reply via email to