How you approach this will depend substantially on the sequence identity between your target and your potential MR models. Definitely remove all non-protein atoms from your search model, as these are not likely at all to be present, or present at these positions, in your target. In addition to using a program like Chainsaw to truncate your model, you might also consider using models truncated at the N- or C-terminus (if these are relatively mobile or ill-defined), or consider searching with multimers (e.g., dimers) for targets that are homo-oligomers with expected quaternary structure symmetry. For difficult targets in which there were significant gaps and insertions in the target compared to the available search models, we used homology-based protein folding prediction (e.g., Phyre) to prepare search models. For marginal models, it is possible to get a reasonable crude solution using MR, followed by density modification and autobuilding to trace a better solution (e.g. PARROT & BUCCANEER), especially if you have NCS in your target. This worked really nicely for us for 3UAO, where search models had 30% or less identity.

Cheers,

_______________________________________
Roger S. Rowlett
Gordon & Dorothy Kline Professor
Department of Chemistry
Colgate University
13 Oak Drive
Hamilton, NY 13346

tel: (315)-228-7245
ofc: (315)-228-7395
fax: (315)-228-7935
email: rrowl...@colgate.edu

On 1/6/2015 8:41 AM, vellieux wrote:
Hello,

Keeping the waters in a model used for molecular replacement search is not a very good idea.

I'd suggest first that you use a program like Chainsaw and possibly additional programs to fine-tune your search model to the problem that you are trying to solve.

Also, reading material such as the ccp4 study weekend proceedings devoted to molecular replacement and similar material (that are available on the internet) would be a good idea as well. The problems you are encountering have been discussed in the literature.

Fred.


On 06/01/15 13:06, allen price wrote:

Dear all:

I got a dataset at 2.8 angstron. I have tried several ways such as phaser, MRBUMP,BALBES,but still can't solve the

data,which means I have to edit my model. Maybe I'd better cut it off or delete the water or loop. I really have no

idea,as it is my first time to do such things, I alway used the whole model to mr. Could anyone give me some advice?

what kind  of software do you guys use? really need you help!

Best regards,

Allen


--
Fred. Vellieux (B.Sc., Ph.D., hdr)

IBS / ELMA
Campus EPN
71 avenue des Martyrs
CS 10090
F-38044 Grenoble Cedex 9
Tel: +33 457428605
Fax: +33 476501890

Reply via email to