"What is the best procedure to use for weak anomalous signal"

That opens up the can of worms which I'm happy to jump into.
We've had very good success in the years 2003-2009 with shelx for finding sites 
(sometimes more than 10000 trials) then force feeding them to sharp for phase 
improvement. We should also say most of the times in particular in the more 
difficult cases xds made the difference in detectable anomalous signal.

And no we still have not published this. With we I mean Marc Robien and myself 
during our SGPP times.

Jürgen 
......................
Jürgen Bosch
Johns Hopkins Bloomberg School of Public Health
Department of Biochemistry & Molecular Biology
Johns Hopkins Malaria Research Institute
615 North Wolfe Street, W8708
Baltimore, MD 21205
Phone: +1-410-614-4742
Lab:      +1-410-614-4894
Fax:      +1-410-955-3655
http://lupo.jhsph.edu

On Jan 14, 2013, at 3:13, "James Holton" <jmhol...@lbl.gov> wrote:

> What is the best procedure to use for weak anomalous signal

Reply via email to