> On Nov 10, 2014, at 11:22 AM, Kern Sibbald <k...@sibbald.com> wrote: > > There is no need to modify the code. Just modify the bacula-sd.conf file. > It is much easier. > > Best regards, > Kern
I think Kern refers to here: http://www.bacula.org/5.0.x-manuals/en/main/main/Storage_Daemon_Configuratio.html <http://www.bacula.org/5.0.x-manuals/en/main/main/Storage_Daemon_Configuratio.html> Maximum Changer Wait = time This directive specifies the maximum time in seconds for Bacula to wait for an autochanger to change the volume. If this time is exceeded, Bacula will invalidate the Volume slot number stored in the catalog and try again. If no additional changer volumes exist, Bacula will ask the operator to intervene. The default is 5 minutes. There are several ‘wait’ / ‘time’ options listed there. — Dan Langille
signature.asc
Description: Message signed with OpenPGP using GPGMail
------------------------------------------------------------------------------
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users