Consider a admin job where the drive is cleaned. I'm very confused by the library needing to clean so often. -- Dan Langille http://langille.org/
> On Nov 10, 2014, at 7:45 AM, Andrey Chebotarev <a...@525.su> wrote: > > Ok, may be there is another solution. > Let's put everything in one place: > I have very long jobs, which spend 30-40 cartridges per one. > I have library which have to be configured with auto cleaning. > During running job after several cartridges filled, say 10, library wants to > clean tape and does it automatically. Cleaning takes more than 5 minutes. > Meanwhile bacula is trying to load new cartridges and after 5 minutes fails. > What is the best solution of my issue? > > >> I wanted to change the code by myself. I just wanted to know where is in >> code place where defined 5 minutes timeout. >> >>> >>> >>> >>> On Nov 10, 2014, at 3:33 AM, Andrey Chebotarev <a...@525.su> wrote: >>> >>>> Hi. >>>> It's in devel because the question about editing sources, >>>> but not about configuration. >>>> And I think solve the question could only developer. >>> >>> The conclusion to change the code is premature. >>> >>>> >>>>> >>>>>> On Nov 4, 2014, at 6:55 AM, Andrey Chebotarev <a...@525.su> wrote: >>>>>> >>>>>> >>>>>>> Hi guys. >>>>>>> >>>>>>> I use bacula 5.2.13 with IBM TS3200 library. >>>>>>> >>>>>>> Periodically I face problem with load slot time out. In logs it looks >>>>>>> lilke: >>>>>>> >>>>>>> 22-Sep 00:35 baculasrv-dir JobId 10471: Recycled volume "220AAAL6" >>>>>>> 22-Sep 00:35 baculasrv-sd JobId 10471: 3304 Issuing autochanger "load >>>>>>> slot 1, drive 1" command. >>>>>>> 22-Sep 00:40 baculasrv-sd JobId 10471: Fatal error: 3992 Bad >>>>>>> autochanger "load slot 1, drive 1": ERR=Child died from signal 15: >>>>>>> Termination. >>>>>>> Results=Program killed by Bacula (timeout) >>>>>>> 22-Sep 00:32 sqcompose-fd JobId 10471: Fatal error: backup.c:1019 >>>>>>> Network send error to SD. >>>>>>> >>>>>>> As I understood, bacula tries to load slot for 5 minutes and if it's >>>>>>> not successful stops job. >>>>>>> I started investigation why bacula sometimes doesn't manage to load >>>>>>> slot in 5 minutes and find out library stops responding to commands and >>>>>>> starts cleaning drive procedure which takes more than 5 minutes(Library >>>>>>> was configured to clean drive automatically) >>>>>>> >>>>>>> So how can I solve the problem? >>>>>>> I've found place in mtx-changer script where declared 300 seconds to >>>>>>> wait. I've increased it value to 1800 seconds. Is it only place or I >>>>>>> have to change somthing else in sources? >>>>> >>>>> >>>>>> Hi everybody. >>>>>> Increasing timeout in mtx-changer script hasn't helped, I have the same >>>>>> issue. Where in sources I can increase timeout to 30 minutes? >>>>> >>>>> I don’t see why this is on devel It should be on users, which is cc’d >>>>> here. >> >> >> >> ------------------------------------------------------------------------------ >> >> >> _______________________________________________ >> Bacula-devel mailing list >> bacula-de...@lists.sourceforge.net >> https://lists.sourceforge.net/lists/listinfo/bacula-devel >
------------------------------------------------------------------------------
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users