Consider a admin job where the drive is cleaned.  I'm very confused by the 
library needing to clean so often. 
-- 
Dan Langille
http://langille.org/


> On Nov 10, 2014, at 7:45 AM, Andrey Chebotarev <a...@525.su> wrote:
> 
> Ok, may be there is another solution.
> Let's put everything in one place:
> I have very long jobs, which spend 30-40 cartridges per one.
> I have library which have to be configured with auto cleaning.
> During running job after several cartridges filled, say 10, library wants to 
> clean tape and does it automatically. Cleaning takes more than 5 minutes.
> Meanwhile bacula is trying to load new cartridges and after 5 minutes fails.
> What is the best solution of my issue?
> 
> 
>> I wanted to change the code by myself. I just wanted to know where is in 
>> code place where defined 5 minutes timeout.
>> 
>>> 
>>> 
>>> 
>>> On Nov 10, 2014, at 3:33 AM, Andrey Chebotarev <a...@525.su> wrote:
>>> 
>>>> Hi.
>>>> It's in devel because the question about editing sources,               
>>>> but not about configuration.
>>>> And I think solve the question could only developer.
>>> 
>>> The conclusion to change the code is premature. 
>>> 
>>>> 
>>>>> 
>>>>>> On Nov 4, 2014, at 6:55 AM, Andrey Chebotarev <a...@525.su> wrote:
>>>>>> 
>>>>>> 
>>>>>>> Hi guys.
>>>>>>> 
>>>>>>> I use bacula 5.2.13 with IBM TS3200 library.
>>>>>>> 
>>>>>>> Periodically I face problem with load slot time out. In logs it looks 
>>>>>>> lilke:
>>>>>>> 
>>>>>>> 22-Sep 00:35 baculasrv-dir JobId 10471: Recycled volume "220AAAL6"
>>>>>>> 22-Sep 00:35 baculasrv-sd JobId 10471: 3304 Issuing autochanger "load 
>>>>>>> slot 1, drive 1" command.
>>>>>>> 22-Sep 00:40 baculasrv-sd JobId 10471: Fatal error: 3992 Bad 
>>>>>>> autochanger "load slot 1, drive 1": ERR=Child died from signal 15: 
>>>>>>> Termination.
>>>>>>> Results=Program killed by Bacula (timeout)
>>>>>>> 22-Sep 00:32 sqcompose-fd JobId 10471: Fatal error: backup.c:1019 
>>>>>>> Network send error to SD.
>>>>>>> 
>>>>>>> As I understood, bacula tries to load slot for 5 minutes and if it's 
>>>>>>> not successful stops job.
>>>>>>> I started investigation why bacula sometimes doesn't manage to load 
>>>>>>> slot in 5 minutes and find out library stops responding to commands and 
>>>>>>> starts cleaning drive procedure which takes more than 5 minutes(Library 
>>>>>>> was configured to clean drive automatically)
>>>>>>> 
>>>>>>> So how can I solve the problem?
>>>>>>> I've found place in mtx-changer script where declared 300 seconds to 
>>>>>>> wait. I've increased it value to 1800 seconds. Is it only place or I 
>>>>>>> have to change somthing else in sources?
>>>>> 
>>>>> 
>>>>>> Hi everybody.
>>>>>> Increasing timeout in mtx-changer script hasn't helped, I have the same 
>>>>>> issue. Where in sources I can increase timeout to 30 minutes?
>>>>> 
>>>>> I don’t see why this is on devel  It should be on users, which is cc’d 
>>>>> here.
>> 
>> 
>> 
>> ------------------------------------------------------------------------------
>> 
>> 
>> _______________________________________________
>> Bacula-devel mailing list
>> bacula-de...@lists.sourceforge.net
>> https://lists.sourceforge.net/lists/listinfo/bacula-devel
> 
------------------------------------------------------------------------------
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to