> On Nov 4, 2014, at 6:55 AM, Andrey Chebotarev <a...@525.su > <mailto:a...@525.su>> wrote: > > >> Hi guys. >> >> I use bacula 5.2.13 with IBM TS3200 library. >> >> Periodically I face problem with load slot time out. In logs it looks lilke: >> >> 22-Sep 00:35 baculasrv-dir JobId 10471: Recycled volume "220AAAL6" >> 22-Sep 00:35 baculasrv-sd JobId 10471: 3304 Issuing autochanger "load slot >> 1, drive 1" command. >> 22-Sep 00:40 baculasrv-sd JobId 10471: Fatal error: 3992 Bad autochanger >> "load slot 1, drive 1": ERR=Child died from signal 15: Termination. >> Results=Program killed by Bacula (timeout) >> 22-Sep 00:32 sqcompose-fd JobId 10471: Fatal error: backup.c:1019 Network >> send error to SD. >> >> As I understood, bacula tries to load slot for 5 minutes and if it's not >> successful stops job. >> I started investigation why bacula sometimes doesn't manage to load slot in >> 5 minutes and find out library stops responding to commands and starts >> cleaning drive procedure which takes more than 5 minutes(Library was >> configured to clean drive automatically) >> >> So how can I solve the problem? >> I've found place in mtx-changer script where declared 300 seconds to wait. >> I've increased it value to 1800 seconds. Is it only place or I have to >> change somthing else in sources? >
> Hi everybody. > Increasing timeout in mtx-changer script hasn't helped, I have the same > issue. Where in sources I can increase timeout to 30 minutes? I don’t see why this is on devel It should be on users, which is cc’d here. — Dan Langille
------------------------------------------------------------------------------
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users