Vinícius, One option I just tested is use the relabel command twice. One relabel to any arbitrary volume name (since you can't relabel to the same volume name), and a second relabel to the original volume name witch is acquired from the tape paper label. Don't know if there is better options.
Cheers, On Mon, Aug 18, 2014 at 1:24 PM, Vinicius Alexandre Pereira de Souza < vinicius.apso...@gmail.com> wrote: > Hi Heitor, > > Thanks for help. I tried: update > volume parameters > all volumes from > all pools, but it didn't worked. I don't have an option like "update media > type" also. > > > On Mon, Aug 18, 2014 at 1:14 PM, Heitor Faria <hei...@bacula.com.br> > wrote: > >> >> >> >> The problem now is when my jobs run, it tries to use a media with "Media >>> Type = LTO-5-LibHP08", but all the medias are still configured as "LTO-5". >>> The following log was generated: >>> >>> When i list the media on bconsole, all of them still are LTO-5, after >>> searching for solutions, all i found was people suggesting to update the >>> values manually on database. is there a better way to correct the media >>> type on the medias? >>> >> >> >> Hi Vinicius: did you try the update > volume parameters > all volumes >> from all pools? >> >> >>> >>> >>> Thanks. >>> >>> >>> On Thu, Aug 7, 2014 at 2:39 PM, Roberts, Ben <ben.robe...@gsacapital.com >>> > wrote: >>> >>>> Hi Vinicius, >>>> >>>> >>>> >>>> You need to use a unique Media Type for each autochanger, e.g. >>>> “LTO5-Library1” and “LTO5-Library2”. These are arbitrary string values, the >>>> exact name doesn’t matter. Bacula believes a drive in library1 is suitable >>>> for loading a tape from library2 because the same Media Type is used for >>>> each. >>>> >>>> >>>> >>>> Regards, >>>> >>>> Ben Roberts >>>> >>>> >>>> >>>> *From:* Vinicius Alexandre Pereira de Souza [mailto: >>>> vinicius.apso...@gmail.com] >>>> *Sent:* 07 August 2014 17:39 >>>> *To:* bacula-users@lists.sourceforge.net >>>> *Subject:* [Bacula-users] Bacula Loading Tape at the Wrong Library >>>> >>>> >>>> >>>> Hello everybody, >>>> >>>> I'm new to Bacula, and i'm having a problem using different storages in >>>> a same pool. >>>> >>>> I have two HP Tape Libraries installed on the Storage (LibHP08 and >>>> LibHP09), i tried to configure some jobs to access both libraries, but I'm >>>> having some trouble with bacula accessing the wrong library. >>>> >>>> For example, bacula tries to access volume "G00022L5" on slot 20 at >>>> LibHP08, but it reaches the volume "H00011L5" on slot 20 at LibHP09. >>>> Basically, it tries to get a tape on the correct slot, but in the wrong >>>> Library. It Generates the Following error: >>>> >>>> >>>> >>>> LibHP 3307 Issuing autochanger "unload slot 20, drive 1" command. >>>> >>>> Warning: Director wanted Volume "G00022L5". >>>> >>>> Current Volume "H00011L5" not acceptable because: >>>> >>>> 1998 Volume "H00011L5" catalog status is Append, not in Pool. >>>> >>>> Then, bacula unloads the drive, tries to find the correct tape, but >>>> loads the wrong one, generates the error again, and so on. >>>> >>>> The job never completes, since it doesn't find the correct tape. >>>> >>>> Some of my Pools: >>>> >>>> >>>> >>>> Pool { >>>> >>>> Name = machine-Pool-Weekly >>>> >>>> Pool Type = Backup >>>> >>>> Storage = LibHP08, LibHP09 >>>> >>>> Recycle = yes >>>> >>>> AutoPrune = yes >>>> >>>> Volume Retention = 34 days >>>> >>>> } >>>> >>>> >>>> >>>> Pool { >>>> >>>> Name = machine-Pool-Monthly >>>> >>>> Pool Type = Backup >>>> >>>> Storage = LibHP08, LibHP09 >>>> >>>> Recycle = yes >>>> >>>> AutoPrune = yes >>>> >>>> Volume Retention = 1825 days >>>> >>>> } >>>> >>>> >>>> >>>> Devices/Autochangers Config: >>>> >>>> >>>> >>>> # >>>> >>>> ## An autochanger device with four drives >>>> >>>> ## Library HP (LibHP08) >>>> >>>> ## >>>> >>>> Autochanger { >>>> >>>> Name = LibHP08_Changer >>>> >>>> Device = LibHP08-drive_1, LibHP08-drive_2, LibHP08-drive_3, >>>> LibHP08-drive_4 >>>> >>>> Changer Command = "/usr/lib64/bacula/mtx-changer %c %o %S %a %d" >>>> >>>> Changer Device = /dev/tape/by-id/scsi-35001438016063c04 >>>> >>>> } >>>> >>>> >>>> >>>> # >>>> >>>> ## An autochanger device with four drives >>>> >>>> ## Library HP (LibHP09) >>>> >>>> ## >>>> >>>> Autochanger { >>>> >>>> Name = LibHP09_Changer >>>> >>>> Device = LibHP09-drive_1, LibHP09-drive_2, LibHP09-drive_3, >>>> LibHP09-drive_4 >>>> >>>> Changer Command = "/usr/lib64/bacula/mtx-changer %c %o %S %a %d" >>>> >>>> Changer Device = /dev/tape/by-id/scsi-3500143801606395c >>>> >>>> } >>>> >>>> >>>> >>>> Device { >>>> >>>> Name = LibHP08-drive_1 # >>>> >>>> Drive Index = 0 >>>> >>>> Media Type = LTO-5 >>>> >>>> Archive Device = /dev/tape/by-id/scsi-35001438016063c05-nst >>>> >>>> AutomaticMount = yes; # when device opened, read it >>>> >>>> AlwaysOpen = yes; >>>> >>>> RemovableMedia = yes; >>>> >>>> RandomAccess = no; >>>> >>>> AutoChanger = yes >>>> >>>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>>> >>>> Maximum Changer Wait = 600 >>>> >>>> Maximum Concurrent Jobs = 1 >>>> >>>> LabelMedia = yes >>>> >>>> } >>>> >>>> >>>> >>>> Device { >>>> >>>> Name = LibHP08-drive_2 # >>>> >>>> Drive Index = 1 >>>> >>>> Media Type = LTO-5 >>>> >>>> Archive Device = /dev/tape/by-id/scsi-35001438016063c08-nst >>>> >>>> AutomaticMount = yes; # when device opened, read it >>>> >>>> AlwaysOpen = yes; >>>> >>>> RemovableMedia = yes; >>>> >>>> RandomAccess = no; >>>> >>>> AutoChanger = yes >>>> >>>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>>> >>>> Maximum Changer Wait = 600 >>>> >>>> Maximum Concurrent Jobs = 1 >>>> >>>> LabelMedia = yes >>>> >>>> } >>>> >>>> >>>> >>>> Device { >>>> >>>> Name = LibHP08-drive_3 # >>>> >>>> Drive Index = 2 >>>> >>>> Media Type = LTO-5 >>>> >>>> Archive Device = /dev/tape/by-id/scsi-35001438016063c0b-nst >>>> >>>> AutomaticMount = yes; # when device opened, read it >>>> >>>> AlwaysOpen = yes; >>>> >>>> RemovableMedia = yes; >>>> >>>> RandomAccess = no; >>>> >>>> AutoChanger = yes >>>> >>>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>>> >>>> Maximum Changer Wait = 600 >>>> >>>> Maximum Concurrent Jobs = 1 >>>> >>>> LabelMedia = yes >>>> >>>> } >>>> >>>> >>>> >>>> Device { >>>> >>>> Name = LibHP08-drive_4 # >>>> >>>> Drive Index = 3 >>>> >>>> Media Type = LTO-5 >>>> >>>> Archive Device = /dev/tape/by-id/scsi-35001438016063c0e-nst >>>> >>>> AutomaticMount = yes; # when device opened, read it >>>> >>>> AlwaysOpen = yes; >>>> >>>> RemovableMedia = yes; >>>> >>>> RandomAccess = no; >>>> >>>> AutoChanger = yes >>>> >>>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>>> >>>> Maximum Changer Wait = 600 >>>> >>>> Maximum Concurrent Jobs = 1 >>>> >>>> LabelMedia = yes >>>> >>>> } >>>> >>>> >>>> >>>> Device { >>>> >>>> Name = LibHP09-drive_1 # >>>> >>>> Drive Index = 0 >>>> >>>> Media Type = LTO-5 >>>> >>>> Archive Device = /dev/tape/by-id/scsi-3500143801606395d-nst >>>> >>>> AutomaticMount = yes; # when device opened, read it >>>> >>>> AlwaysOpen = yes; >>>> >>>> RemovableMedia = yes; >>>> >>>> RandomAccess = no; >>>> >>>> AutoChanger = yes >>>> >>>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>>> >>>> Maximum Changer Wait = 600 >>>> >>>> Maximum Concurrent Jobs = 1 >>>> >>>> LabelMedia = yes >>>> >>>> } >>>> >>>> >>>> >>>> Device { >>>> >>>> Name = LibHP09-drive_2 # >>>> >>>> Drive Index = 1 >>>> >>>> Media Type = LTO-5 >>>> >>>> Archive Device = /dev/tape/by-id/scsi-35001438016063960-nst >>>> >>>> AutomaticMount = yes; # when device opened, read it >>>> >>>> AlwaysOpen = yes; >>>> >>>> RemovableMedia = yes; >>>> >>>> RandomAccess = no; >>>> >>>> AutoChanger = yes >>>> >>>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>>> >>>> Maximum Changer Wait = 600 >>>> >>>> Maximum Concurrent Jobs = 1 >>>> >>>> LabelMedia = yes >>>> >>>> } >>>> >>>> >>>> >>>> Device { >>>> >>>> Name = LibHP09-drive_3 # >>>> >>>> Drive Index = 2 >>>> >>>> Media Type = LTO-5 >>>> >>>> Archive Device = /dev/tape/by-id/scsi-35001438016063963-nst >>>> >>>> AutomaticMount = yes; # when device opened, read it >>>> >>>> AlwaysOpen = yes; >>>> >>>> RemovableMedia = yes; >>>> >>>> RandomAccess = no; >>>> >>>> AutoChanger = yes >>>> >>>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>>> >>>> Maximum Changer Wait = 600 >>>> >>>> Maximum Concurrent Jobs = 1 >>>> >>>> LabelMedia = yes >>>> >>>> } >>>> >>>> >>>> >>>> Device { >>>> >>>> Name = LibHP09-drive_4 # >>>> >>>> Drive Index = 3 >>>> >>>> Media Type = LTO-5 >>>> >>>> Archive Device = /dev/tape/by-id/scsi-35001438016063966-nst >>>> >>>> AutomaticMount = yes; # when device opened, read it >>>> >>>> AlwaysOpen = yes; >>>> >>>> RemovableMedia = yes; >>>> >>>> RandomAccess = no; >>>> >>>> AutoChanger = yes >>>> >>>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>>> >>>> Maximum Changer Wait = 600 >>>> >>>> Maximum Concurrent Jobs = 1 >>>> >>>> LabelMedia = yes >>>> >>>> } >>>> >>>> Storage config: >>>> >>>> >>>> >>>> Storage { >>>> >>>> Name = LibHP08 >>>> >>>> Address = sd-host >>>> >>>> SDPort = 9103 >>>> >>>> Password = "myPassword" >>>> >>>> Device = LibHP08_Changer >>>> >>>> Media Type = LTO-5 >>>> >>>> Autochanger = yes >>>> >>>> Maximum Concurrent Jobs = 4 >>>> >>>> } >>>> >>>> >>>> >>>> Storage { >>>> >>>> Name = LibHP09 >>>> >>>> Address = sd-host >>>> >>>> SDPort = 9103 >>>> >>>> Password = "myPassword" >>>> >>>> Device = LibHP09_Changer >>>> >>>> Media Type = LTO-5 >>>> >>>> Autochanger = yes >>>> >>>> Maximum Concurrent Jobs = 4 >>>> >>>> } >>>> >>>> At bconsole, i executed the following: >>>> >>>> >>>> >>>> update slots >>>> >>>> There was some tapes at the wrong place, it updated the catalog, but >>>> the error persists. >>>> >>>> I'm Currently using Bacula v5.2.12, I've installed the Director and the >>>> Storage on different machines, both of them communicating with no problems >>>> >>>> Any ideas? >>>> >>>> >>>> >>>> I also created a question at Serverfault: >>>> >>>> http://serverfault.com/questions/618720/ >>>> >>>> >>>> >>>> Thanks in advance! >>>> >>>> -- >>>> >>>> Att, >>>> >>>> Vinicius Alexandre Pereira de Souza >>>> >>>> >>>> >>>> ------------------------------ >>>> This email and any files transmitted with it contain confidential and >>>> proprietary information and is solely for the use of the intended >>>> recipient. If you are not the intended recipient please return the email to >>>> the sender and delete it from your computer and you must not use, disclose, >>>> distribute, copy, print or rely on this email or its contents. This >>>> communication is for informational purposes only. It is not intended as an >>>> offer or solicitation for the purchase or sale of any financial instrument >>>> or as an official confirmation of any transaction. Any comments or >>>> statements made herein do not necessarily reflect those of GSA Capital. GSA >>>> Capital Partners LLP is authorised and regulated by the Financial Conduct >>>> Authority and is registered in England and Wales at Stratton House, 5 >>>> Stratton Street, London W1J 8LA, number OC309261. GSA Capital Services >>>> Limited is registered in England and Wales at the same address, number >>>> 5320529. >>>> >>>> >>> >>> >>> -- >>> Att, >>> Vinicius Alexandre Pereira de Souza >>> >>> >>> >>> ------------------------------------------------------------------------------ >>> >>> _______________________________________________ >>> Bacula-users mailing list >>> Bacula-users@lists.sourceforge.net >>> https://lists.sourceforge.net/lists/listinfo/bacula-users >>> >>> >> >> >> -- >> ============================================ >> Heitor Medrado de Faria | Need Bacula training? 10% discount coupon code >> at Udemy: bacula-users >> <https://www.udemy.com/bacula-backup-software/?couponCode=bacula-users> >> +55 61 2021-8260 >> +55 61 8268-4220 >> Site: www.bacula.com.br >> Facebook: heitor.faria <http://www.facebook.com/heitor.faria> >> Gtalk: heitorfa...@gmail.com >> ============================================ >> > > > > -- > Att, > Vinicius Alexandre Pereira de Souza > > -- ============================================ Heitor Medrado de Faria | Need Bacula training? 10% discount coupon code at Udemy: bacula-users <https://www.udemy.com/bacula-backup-software/?couponCode=bacula-users> +55 61 2021-8260 +55 61 8268-4220 Site: www.bacula.com.br Facebook: heitor.faria <http://www.facebook.com/heitor.faria> Gtalk: heitorfa...@gmail.com ============================================
------------------------------------------------------------------------------
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users