Hi Heitor, Thanks for help. I tried: update > volume parameters > all volumes from all pools, but it didn't worked. I don't have an option like "update media type" also.
On Mon, Aug 18, 2014 at 1:14 PM, Heitor Faria <hei...@bacula.com.br> wrote: > > > > The problem now is when my jobs run, it tries to use a media with "Media >> Type = LTO-5-LibHP08", but all the medias are still configured as "LTO-5". >> The following log was generated: >> >> When i list the media on bconsole, all of them still are LTO-5, after >> searching for solutions, all i found was people suggesting to update the >> values manually on database. is there a better way to correct the media >> type on the medias? >> > > > Hi Vinicius: did you try the update > volume parameters > all volumes from > all pools? > > >> >> >> Thanks. >> >> >> On Thu, Aug 7, 2014 at 2:39 PM, Roberts, Ben <ben.robe...@gsacapital.com> >> wrote: >> >>> Hi Vinicius, >>> >>> >>> >>> You need to use a unique Media Type for each autochanger, e.g. >>> “LTO5-Library1” and “LTO5-Library2”. These are arbitrary string values, the >>> exact name doesn’t matter. Bacula believes a drive in library1 is suitable >>> for loading a tape from library2 because the same Media Type is used for >>> each. >>> >>> >>> >>> Regards, >>> >>> Ben Roberts >>> >>> >>> >>> *From:* Vinicius Alexandre Pereira de Souza [mailto: >>> vinicius.apso...@gmail.com] >>> *Sent:* 07 August 2014 17:39 >>> *To:* bacula-users@lists.sourceforge.net >>> *Subject:* [Bacula-users] Bacula Loading Tape at the Wrong Library >>> >>> >>> >>> Hello everybody, >>> >>> I'm new to Bacula, and i'm having a problem using different storages in >>> a same pool. >>> >>> I have two HP Tape Libraries installed on the Storage (LibHP08 and >>> LibHP09), i tried to configure some jobs to access both libraries, but I'm >>> having some trouble with bacula accessing the wrong library. >>> >>> For example, bacula tries to access volume "G00022L5" on slot 20 at >>> LibHP08, but it reaches the volume "H00011L5" on slot 20 at LibHP09. >>> Basically, it tries to get a tape on the correct slot, but in the wrong >>> Library. It Generates the Following error: >>> >>> >>> >>> LibHP 3307 Issuing autochanger "unload slot 20, drive 1" command. >>> >>> Warning: Director wanted Volume "G00022L5". >>> >>> Current Volume "H00011L5" not acceptable because: >>> >>> 1998 Volume "H00011L5" catalog status is Append, not in Pool. >>> >>> Then, bacula unloads the drive, tries to find the correct tape, but >>> loads the wrong one, generates the error again, and so on. >>> >>> The job never completes, since it doesn't find the correct tape. >>> >>> Some of my Pools: >>> >>> >>> >>> Pool { >>> >>> Name = machine-Pool-Weekly >>> >>> Pool Type = Backup >>> >>> Storage = LibHP08, LibHP09 >>> >>> Recycle = yes >>> >>> AutoPrune = yes >>> >>> Volume Retention = 34 days >>> >>> } >>> >>> >>> >>> Pool { >>> >>> Name = machine-Pool-Monthly >>> >>> Pool Type = Backup >>> >>> Storage = LibHP08, LibHP09 >>> >>> Recycle = yes >>> >>> AutoPrune = yes >>> >>> Volume Retention = 1825 days >>> >>> } >>> >>> >>> >>> Devices/Autochangers Config: >>> >>> >>> >>> # >>> >>> ## An autochanger device with four drives >>> >>> ## Library HP (LibHP08) >>> >>> ## >>> >>> Autochanger { >>> >>> Name = LibHP08_Changer >>> >>> Device = LibHP08-drive_1, LibHP08-drive_2, LibHP08-drive_3, >>> LibHP08-drive_4 >>> >>> Changer Command = "/usr/lib64/bacula/mtx-changer %c %o %S %a %d" >>> >>> Changer Device = /dev/tape/by-id/scsi-35001438016063c04 >>> >>> } >>> >>> >>> >>> # >>> >>> ## An autochanger device with four drives >>> >>> ## Library HP (LibHP09) >>> >>> ## >>> >>> Autochanger { >>> >>> Name = LibHP09_Changer >>> >>> Device = LibHP09-drive_1, LibHP09-drive_2, LibHP09-drive_3, >>> LibHP09-drive_4 >>> >>> Changer Command = "/usr/lib64/bacula/mtx-changer %c %o %S %a %d" >>> >>> Changer Device = /dev/tape/by-id/scsi-3500143801606395c >>> >>> } >>> >>> >>> >>> Device { >>> >>> Name = LibHP08-drive_1 # >>> >>> Drive Index = 0 >>> >>> Media Type = LTO-5 >>> >>> Archive Device = /dev/tape/by-id/scsi-35001438016063c05-nst >>> >>> AutomaticMount = yes; # when device opened, read it >>> >>> AlwaysOpen = yes; >>> >>> RemovableMedia = yes; >>> >>> RandomAccess = no; >>> >>> AutoChanger = yes >>> >>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>> >>> Maximum Changer Wait = 600 >>> >>> Maximum Concurrent Jobs = 1 >>> >>> LabelMedia = yes >>> >>> } >>> >>> >>> >>> Device { >>> >>> Name = LibHP08-drive_2 # >>> >>> Drive Index = 1 >>> >>> Media Type = LTO-5 >>> >>> Archive Device = /dev/tape/by-id/scsi-35001438016063c08-nst >>> >>> AutomaticMount = yes; # when device opened, read it >>> >>> AlwaysOpen = yes; >>> >>> RemovableMedia = yes; >>> >>> RandomAccess = no; >>> >>> AutoChanger = yes >>> >>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>> >>> Maximum Changer Wait = 600 >>> >>> Maximum Concurrent Jobs = 1 >>> >>> LabelMedia = yes >>> >>> } >>> >>> >>> >>> Device { >>> >>> Name = LibHP08-drive_3 # >>> >>> Drive Index = 2 >>> >>> Media Type = LTO-5 >>> >>> Archive Device = /dev/tape/by-id/scsi-35001438016063c0b-nst >>> >>> AutomaticMount = yes; # when device opened, read it >>> >>> AlwaysOpen = yes; >>> >>> RemovableMedia = yes; >>> >>> RandomAccess = no; >>> >>> AutoChanger = yes >>> >>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>> >>> Maximum Changer Wait = 600 >>> >>> Maximum Concurrent Jobs = 1 >>> >>> LabelMedia = yes >>> >>> } >>> >>> >>> >>> Device { >>> >>> Name = LibHP08-drive_4 # >>> >>> Drive Index = 3 >>> >>> Media Type = LTO-5 >>> >>> Archive Device = /dev/tape/by-id/scsi-35001438016063c0e-nst >>> >>> AutomaticMount = yes; # when device opened, read it >>> >>> AlwaysOpen = yes; >>> >>> RemovableMedia = yes; >>> >>> RandomAccess = no; >>> >>> AutoChanger = yes >>> >>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>> >>> Maximum Changer Wait = 600 >>> >>> Maximum Concurrent Jobs = 1 >>> >>> LabelMedia = yes >>> >>> } >>> >>> >>> >>> Device { >>> >>> Name = LibHP09-drive_1 # >>> >>> Drive Index = 0 >>> >>> Media Type = LTO-5 >>> >>> Archive Device = /dev/tape/by-id/scsi-3500143801606395d-nst >>> >>> AutomaticMount = yes; # when device opened, read it >>> >>> AlwaysOpen = yes; >>> >>> RemovableMedia = yes; >>> >>> RandomAccess = no; >>> >>> AutoChanger = yes >>> >>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>> >>> Maximum Changer Wait = 600 >>> >>> Maximum Concurrent Jobs = 1 >>> >>> LabelMedia = yes >>> >>> } >>> >>> >>> >>> Device { >>> >>> Name = LibHP09-drive_2 # >>> >>> Drive Index = 1 >>> >>> Media Type = LTO-5 >>> >>> Archive Device = /dev/tape/by-id/scsi-35001438016063960-nst >>> >>> AutomaticMount = yes; # when device opened, read it >>> >>> AlwaysOpen = yes; >>> >>> RemovableMedia = yes; >>> >>> RandomAccess = no; >>> >>> AutoChanger = yes >>> >>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>> >>> Maximum Changer Wait = 600 >>> >>> Maximum Concurrent Jobs = 1 >>> >>> LabelMedia = yes >>> >>> } >>> >>> >>> >>> Device { >>> >>> Name = LibHP09-drive_3 # >>> >>> Drive Index = 2 >>> >>> Media Type = LTO-5 >>> >>> Archive Device = /dev/tape/by-id/scsi-35001438016063963-nst >>> >>> AutomaticMount = yes; # when device opened, read it >>> >>> AlwaysOpen = yes; >>> >>> RemovableMedia = yes; >>> >>> RandomAccess = no; >>> >>> AutoChanger = yes >>> >>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>> >>> Maximum Changer Wait = 600 >>> >>> Maximum Concurrent Jobs = 1 >>> >>> LabelMedia = yes >>> >>> } >>> >>> >>> >>> Device { >>> >>> Name = LibHP09-drive_4 # >>> >>> Drive Index = 3 >>> >>> Media Type = LTO-5 >>> >>> Archive Device = /dev/tape/by-id/scsi-35001438016063966-nst >>> >>> AutomaticMount = yes; # when device opened, read it >>> >>> AlwaysOpen = yes; >>> >>> RemovableMedia = yes; >>> >>> RandomAccess = no; >>> >>> AutoChanger = yes >>> >>> Alert Command = "sh -c 'smartctl -H -l error %c'" >>> >>> Maximum Changer Wait = 600 >>> >>> Maximum Concurrent Jobs = 1 >>> >>> LabelMedia = yes >>> >>> } >>> >>> Storage config: >>> >>> >>> >>> Storage { >>> >>> Name = LibHP08 >>> >>> Address = sd-host >>> >>> SDPort = 9103 >>> >>> Password = "myPassword" >>> >>> Device = LibHP08_Changer >>> >>> Media Type = LTO-5 >>> >>> Autochanger = yes >>> >>> Maximum Concurrent Jobs = 4 >>> >>> } >>> >>> >>> >>> Storage { >>> >>> Name = LibHP09 >>> >>> Address = sd-host >>> >>> SDPort = 9103 >>> >>> Password = "myPassword" >>> >>> Device = LibHP09_Changer >>> >>> Media Type = LTO-5 >>> >>> Autochanger = yes >>> >>> Maximum Concurrent Jobs = 4 >>> >>> } >>> >>> At bconsole, i executed the following: >>> >>> >>> >>> update slots >>> >>> There was some tapes at the wrong place, it updated the catalog, but >>> the error persists. >>> >>> I'm Currently using Bacula v5.2.12, I've installed the Director and the >>> Storage on different machines, both of them communicating with no problems >>> >>> Any ideas? >>> >>> >>> >>> I also created a question at Serverfault: >>> >>> http://serverfault.com/questions/618720/ >>> >>> >>> >>> Thanks in advance! >>> >>> -- >>> >>> Att, >>> >>> Vinicius Alexandre Pereira de Souza >>> >>> >>> >>> ------------------------------ >>> This email and any files transmitted with it contain confidential and >>> proprietary information and is solely for the use of the intended >>> recipient. If you are not the intended recipient please return the email to >>> the sender and delete it from your computer and you must not use, disclose, >>> distribute, copy, print or rely on this email or its contents. This >>> communication is for informational purposes only. It is not intended as an >>> offer or solicitation for the purchase or sale of any financial instrument >>> or as an official confirmation of any transaction. Any comments or >>> statements made herein do not necessarily reflect those of GSA Capital. GSA >>> Capital Partners LLP is authorised and regulated by the Financial Conduct >>> Authority and is registered in England and Wales at Stratton House, 5 >>> Stratton Street, London W1J 8LA, number OC309261. GSA Capital Services >>> Limited is registered in England and Wales at the same address, number >>> 5320529. >>> >>> >> >> >> -- >> Att, >> Vinicius Alexandre Pereira de Souza >> >> >> >> ------------------------------------------------------------------------------ >> >> _______________________________________________ >> Bacula-users mailing list >> Bacula-users@lists.sourceforge.net >> https://lists.sourceforge.net/lists/listinfo/bacula-users >> >> > > > -- > ============================================ > Heitor Medrado de Faria | Need Bacula training? 10% discount coupon code > at Udemy: bacula-users > <https://www.udemy.com/bacula-backup-software/?couponCode=bacula-users> > +55 61 2021-8260 > +55 61 8268-4220 > Site: www.bacula.com.br > Facebook: heitor.faria <http://www.facebook.com/heitor.faria> > Gtalk: heitorfa...@gmail.com > ============================================ > -- Att, Vinicius Alexandre Pereira de Souza
------------------------------------------------------------------------------
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users