Mike,
I think I'll have to upgrade to v7 and a some 2216 units. Guess it is time to
try to integrate some v7 units into the v6 network and see what happens.
--
Best regards,
Mark mailto:[email protected]
Myakka Communications
www.Myakka.com
------
Thursday, April 20, 2023, 10:10:32 AM, you wrote:
> Years ago on ROX v6 on a 1036, it would take 5 - 10 minutes for /ip route
> print to reflect an upstream change and then another 5 - 10 minutes for the
> traffic to actually change directions.
> -----
> Mike Hammett
> Intelligent Computing Solutions
> Midwest Internet Exchange
> The Brothers WISP
> From: "Josh Luthman" <[email protected]>
> To: "AnimalFarm Microwave Users Group" <[email protected]>
> Sent: Wednesday, April 19, 2023 12:25:14 PM
> Subject: Re: [AFMUG] BGP Question
> I want to say my old x86 would do full tables in 3 minutes...that's been a
> while.
> I think the CCR1009/1036/1072 is a couple of minutes, I don't think it's
> 10-15 though.
> On Wed, Apr 19, 2023 at 11:20 AM Mark - Myakka Technologies <[email protected]>
> wrote:
>> Dennis,
>> Using mikrotik routers.
>> Two MaxxWave x86 i5 8 core 10 years old v6.47.9
>> One CCR1072 v6.47.9
>> Yes taking full tables.
>> Tried BFD while back. Didn't seem that my upstream was supporting it.
>> Never established a session.
>> Thinking I may need to start looking at new hardware and v7. But before I
>> go that route, what should I expect if I do get 3 brand new CCR2116-12G-4S+
>> running v7.
>> --
>> Best regards,
>> Mark mailto:[email protected]
>> Myakka Communications
>> www.Myakka.com
>> ------
>> Wednesday, April 19, 2023, 11:08:45 AM, you wrote:
DB>>> Really depends on a lot of things.
DB>>> 1.What router are you using?
DB>>> 2. Are you taking full tables from all of your upstreams?
DB>>> 3. Are you not using BFD ?
DB>>> 4. What version of RouterOS are you using?
DB>>> V7 will be faster, 2216 will be faster than a 1036, your hold time is
kinda long..
DB>>> Dennis Burgess, Mikrotik Certified Trainer
DB>>> MTCNA, MTCRE, MTCWE, MTCTCE, MTCINE, MTCSE, HE IPv6 Sage, Cambium ePMP
Certified
DB>>> Author of "Learn RouterOS- Second Edition"
DB>>> Link Technologies, Inc -- Mikrotik & WISP Support Services
DB>>> Office: 314-735-0270 Website: http://www.linktechs.net
DB>>> Need to Automate MikroTik Backups: https://cloud.linktechs.net
DB>>> Create Wireless Coverage's with www.towercoverage.com
DB>>> -----Original Message-----
DB>>> From: AF <[email protected]> On Behalf Of Mark - Myakka Technologies
DB>>> Sent: Wednesday, April 19, 2023 9:48 AM
DB>>> To: [email protected]
DB>>> Subject: [AFMUG] BGP Question
DB>>> We have two circuits coming into our NOC. We peer with 3 different
providers on each circuit. If a circuit fails, BGP will do it's magic and
traffic will start flowing though the surviving circuit.
DB>>> However, we seemed to get about 5 - 10 minutes of unstable Internet while
this is happening. Is this normal? If not, what can I do to speed up the
process? Is it a function of my routers having to rebuild routes? Will new
faster routers help? Is it a function of timers? Keep-Alive is 30s and hold
is at 90s. Should I investigate BFD?
DB>>> How fast could I expect to get this fail-over to work under best
conditions?
DB>>> Thanks,
DB>>> Mark mailto:[email protected]
DB>>> Myakka Communications
DB>>>
https://imsva91-ctp.trendmicro.com:443/wis/clicktime/v1/query?url=www.Myakka.com&umid=08E7599C-F9B1-CC05-BF9C-94CA5B14AB1B&auth=079c058f437b7c6303d36c6513e5e8848d0c5ac4-1a5796e3447e2e1707012b957aa10dd6970458d5
DB>>> --
DB>>> AF mailing list
DB>>> [email protected]
DB>>> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
--
AF mailing list
[email protected]
http://af.afmug.com/mailman/listinfo/af_af.afmug.com