Talk to Evan at Cambium, he'll be the single best person to give you those steps. I can give you my notes I took from how he explained I should transition from Cloud to On Prem if you'd like.
As far as leaking water I think Mark is talking about 450 and/or 450i. The 450m 5 GHz had a water problem with the glands but the 450m 3 GHz doesn't have that (per Matt at Cambium). Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Mon, Aug 10, 2020 at 10:05 AM Mark Radabaugh <m...@amplex.net> wrote: > No answer to your SBRS question but… eventually the old style 450 case > leaks water and the first place it goes is right down the center pin of the > RF connector and into the cable. Silicon caulk and/or electrical tape > along the top and side gaps goes a long way toward keeping the water out. > > Happens on 5.7 and 3.65 > > Mark > > On Aug 10, 2020, at 9:46 AM, Ken Hohhof <af...@kwisp.com> wrote: > > Has anyone figured out the best procedure for replacing a Cambium CBRS AP? > > I’m guessing there is something more elegant and less disruptive than > deleting the whole sector while the tech is swapping out the AP and then re > importing into cnMaestro from a spreadsheet and hoping everything goes > smoothly and customers are only down for a few minutes. > > I’m talking about replacing an AP that is in service but with issues. > Over the years we’ve run into RF issues with the original connectorized 450 > APs. I’ve never established whether it’s the AP or the sector antenna, but > replacing it solves the modulation and V/H ratio issues. > > The same procedure would also apply if you are upgrading to a 450i or 450m > AP. > -- > AF mailing list > AF@af.afmug.com > http://af.afmug.com/mailman/listinfo/af_af.afmug.com > > > -- > AF mailing list > AF@af.afmug.com > http://af.afmug.com/mailman/listinfo/af_af.afmug.com >
-- AF mailing list AF@af.afmug.com http://af.afmug.com/mailman/listinfo/af_af.afmug.com