Talk to Evan at Cambium, he'll be the single best person to give you those
steps.  I can give you my notes I took from how he explained I should
transition from Cloud to On Prem if you'd like.

As far as leaking water I think Mark is talking about 450 and/or 450i.  The
450m 5 GHz had a water problem with the glands but the 450m 3 GHz doesn't
have that (per Matt at Cambium).

Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373


On Mon, Aug 10, 2020 at 10:05 AM Mark Radabaugh <m...@amplex.net> wrote:

> No answer to your SBRS question but… eventually the old style 450 case
> leaks water and the first place it goes is right down the center pin of the
> RF connector and into the cable.    Silicon caulk and/or electrical tape
> along the top and side gaps goes a long way toward keeping the water out.
>
> Happens on 5.7 and 3.65
>
> Mark
>
> On Aug 10, 2020, at 9:46 AM, Ken Hohhof <af...@kwisp.com> wrote:
>
> Has anyone figured out the best procedure for replacing a Cambium CBRS AP?
>
> I’m guessing there is something more elegant and less disruptive than
> deleting the whole sector while the tech is swapping out the AP and then re
> importing into cnMaestro from a spreadsheet and hoping everything goes
> smoothly and customers are only down for a few minutes.
>
> I’m talking about replacing an AP that is in service but with issues.
> Over the years we’ve run into RF issues with the original connectorized 450
> APs.  I’ve never established whether it’s the AP or the sector antenna, but
> replacing it solves the modulation and V/H ratio issues.
>
> The same procedure would also apply if you are upgrading to a 450i or 450m
> AP.
> --
> AF mailing list
> AF@af.afmug.com
> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>
>
> --
> AF mailing list
> AF@af.afmug.com
> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>
-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to