100-120 customers or so in the 90deg.  For the most part, customers are
decent, but some would need to be re-aligned most likely could probably
find 40Mhz if needed.  What is your go-to SM for 450M now?

On Wed, Jun 19, 2019 at 12:44 PM Ken Hohhof <af...@kwisp.com> wrote:

> How many is a large number?  You’ll probably gain more with 50 or 100 subs
> than you will with 10.
>
>
>
> And would you be switching over good, high modulation customers?  My
> observation is get all your subs to 6X or 8X before putting them on a
> 450m.  Also, hard to prove, but I think the antenna gain might be flatter
> across the 90 degrees with a 450m than with a traditional sector.  You lose
> something like 2 dB, but in the center, not at the edges.  I don’t have
> precise data to substantiate that though.
>
>
>
> Any chance you could find 40 MHz of spectrum for the 450m?
>
>
>
>
>
> *From:* AF <af-boun...@af.afmug.com> *On Behalf Of *Josh Baird
> *Sent:* Wednesday, June 19, 2019 11:24 AM
> *To:* AFMUG <af@af.afmug.com>
> *Subject:* [AFMUG] When to consider 450M?
>
>
>
> We have a site that has 3-4 fairly loaded ePMP 2K sectors (30 deg horns).
> There are a large number of customers in a single 90 degrees.  While we
> could probably upgrade to ePMP 3K to get a bit of a boost, there is still a
> cost associated in replacing all the CPE to get the full benefit.
>
>
>
> At this point, we're trying to determine if something like 450M makes
> sense for this 90 degrees of coverage.  The cost is obviously much higher,
> but I think it may be a better solution in the long run. If we could find a
> spare 20Mhz, we could run both our existing ePMP radios and the 450M at the
> same time while we cut subscribers over.
>
>
>
> Are there other people here who have been in similar situations and have
> deployed 450M?  I realize the performance of the 450M is dependent upon CPE
> locations, but overall, were you happy with the boost in performance in
> general?  I feel like most people who have upgraded to 450M were already
> running 450, so you didn't really have to forklift all CPE.  If that were
> the case, I think it would be a no-brainer.
>
>
>
> Interested in hearing any success (or failure) stories about people who
> have upgraded to 450M...
>
>
>
>
> --
> AF mailing list
> AF@af.afmug.com
> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>
-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to