Yes, it's bme280wx from WJCarpenter
<https://gitlab.com/wjcarpenter/bme280wx/-/blob/master/README.md>.
In ~weewx/weewx-data/bin/user/bme280wx.py I changed:
# loginf('BME280 data %s' % bme280data)
logdbg('BME280 data %s' % bme280data)
But no change (debug=0):
Dez 02 18:42:46 raspberrypi-W weewxd.py[394495]: bme280: {'outHumidity':
98.0, 'outTemp': 5.1, 'windDir': 135.0, 'rain_total': 910.0, 'windSpeed':
0.0, 'outTempBatteryStatus': 1, 'dateTime': 1764697363, 'usUnits': 17,
'rain': 0.0, 'pressure': 996.8794121453019, 'inTemp': 20.87991048009717,
'inHumidity': 47.00716895052753}
Dez 02 18:42:59 raspberrypi-W weewxd.py[394495]: bme280: BME280 data
compensated_reading(id=90b874ac-5f0e-4dee-ab91-6ff37be85f0f,
timestamp=2025-12-02 17:42:59.009837UTC, temp=20.905 °C, pressure=996.95
hPa, humidity=47.03 % rH)
Dez 02 18:42:59 raspberrypi-W weewxd.py[394495]: bme280: {'outHumidity':
98.0, 'outTemp': 5.1, 'windDir': 135.0, 'rain_total': 910.0, 'windSpeed':
0.0, 'outTempBatteryStatus': 1, 'dateTime': 1764697375, 'usUnits': 17,
'rain': 0.0, 'pressure': 996.9454680536317, 'inTemp': 20.905063962284476,
'inHumidity': 47.0306761168033}
Dez 02 18:43:10 raspberrypi-W weewxd.py[394495]: bme280: BME280 data
compensated_reading(id=e62d5c77-9d93-45ca-a37c-f2050e454beb,
timestamp=2025-12-02 17:43:10.939289UTC, temp=20.870 °C, pressure=996.95
hPa, humidity=47.02 % rH)
This looks to me, like the log-messages are written by weewxd.py.
vince schrieb am Dienstag, 2. Dezember 2025 um 17:48:49 UTC+1:
> You didn't say which bme280 driver you are using, but if you are using the
> one from WJCarpenter there are a couple places in the new_loop_packet( )
> routine that use loginf( ) to log every packet twice. You could change
> that to logdbg( ) in each place to quiet it down to only logging if you
> have debug=1 in weewx.conf
>
> On Tuesday, December 2, 2025 at 2:07:30 AM UTC-8 Zed wrote:
>
>> I had to upgrade my VEnv-installation from 4.9.1 to 5.2.0.
>> Since then for every measurement i see a record like these in the log:
>> Dez 01 23:36:59 server weewxd.py[165343]: bme280: {'outHumidity': 84.0,
>> 'outTemp': 2.6, 'windDir': 180.0, 'rain_total': 908.8, 'windSpeed': 0.0,
>> 'outTempBatteryStatus': 1, 'dateTime': 1764628616, 'usUnits': 17, 'rain':
>> None, 'pressure': 997.3836082289309, 'inTemp': 19.531694481620796,
>> 'inHumidity': 48.77856343381041}
>> Dez 01 23:37:11 server weewxd.py[165343]: bme280: BME280 data
>> compensated_reading(id=2e17ef34-6cf1-4a6c-9198-e2754bdbd3b3,
>> timestamp=2025-12-01 22:37:11.402537UTC, temp=19.512 °C, pressure=997.33
>> hPa, humidity=49.07 % rH)
>> Dez 01 23:37:11 server weewxd.py[165343]: bme280: {'outHumidity': 84.0,
>> 'outTemp': 2.6, 'windDir': 180.0, 'rain_total': 908.8, 'windSpeed': 0.0,
>> 'outTempBatteryStatus': 1, 'dateTime': 1764628628, 'usUnits': 17, 'rain':
>> 0.0, 'pressure': 997.3252012242718, 'inTemp': 19.511572013102704,
>> 'inHumidity': 49.071948952003744}
>>
>> No matter what debug-level is set.
>> Is there a switch to turn these messages off?
>
>
--
You received this message because you are subscribed to the Google Groups
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email
to [email protected].
To view this discussion visit
https://groups.google.com/d/msgid/weewx-user/b4c7110d-65e7-4b4e-91b8-71e49ee157bbn%40googlegroups.com.