En effet je ne comprends pas pourquoi je ne recupere pas "soil_moist1" (surtout que c'est la sonde fournie avec la station !) la 2eme est celle venant de mon ancienne station FROGGIT WH-6000
Feb 24 17:36:14 meteo-Ubuntu weewx-BRESSER[78539] DEBUG user.interceptor: GET: ID=XXXXX&PASSWORD=XXXX&action=updateraww &realtime=1 &rtfreq=5 &dateutc=now &baromin=30.16 &tempf=48.9 &humidity=67 &windspeedmph=3.5 &windgustmph=4.0 &winddir=348 &dewptf=38.3 &rainin=0 &dailyrainin=0.110 &indoortempf=68.0 &indoorhumidity=56 &UV=0 &solarradiation=53.1100 &soiltempf=67.1 &soilmoisture=59 &soiltemp2f=70.8 &soilmoisture2=60 Voici les data du broker MQTT Mosquitto : je les récupère bien :) { "dateTime": "1708796739.0", "barometer_mbar": "1022.0119463308273", "outHumidity": "75.0", "inHumidity": "56.0", "outTemp_C": "7.666666666666665", "inTemp_C": "19.888888888888886", "windSpeed_kph": "0.0", "windGust_kph": "0.0", "radiation_Wpm2": "3.72", "dewpoint_C": "3.4999999999999982", "rain_cm": "0.0", "UV": "0.0", "extraTemp1_C": "19.555555555555557", "extraTemp2_C": "21.5", "extraHumid2": "60.0", "soilTemp1_C": "19.555555555555557", "soilTemp2_C": "21.5", "soilMoist2_centibar": "60.0", "pressure_mbar": "1016.6418288107507", "altimeter_mbar": "1021.9243498035909", "appTemp_C": "6.258531406558916", "cloudbase_meter": "560.1920276267181", "heatindex_C": "6.44722222222222", "humidex_C": "7.666666666666665", "inDewpoint_C": "10.846055159346296", "maxSolarRad_Wpm2": "0.004647852952143922", "rainRate_cm_per_hour": "0.0", "windchill_C": "7.666666666666665", "hourRain_cm": "0.0", "rain24_cm": "0.2794", "dayRain_cm": "0.2794", "usUnits": "16.0" } Le samedi 24 février 2024 à 17:01:50 UTC+1, Remy LAVABRE a écrit : > Ok;.. Va pour la version FR. > > 1/ Dans le paquet généré il y a bien un "soil_most2" mais je ne vois pas > de "soil_moist1". Dans le RAW c'est la même chose : 'soil_moisture_2' mais > pas vu de 'soil_moisture_1' > Avant d'aller plus loin, il y a peut-être déjà là quelque chose à > regarder qui ne marche pas bien... ? > > 2/ Dans la config de weewx, une fois résolu le point 1/, dans la section > [interceptor], j'aurais tendance à essayer la chose suivante : > > [Interceptor] > driver = user.interceptor > device_type = xxxxx > ... > [[sensor_map_extensions]] > ... > extraTemp1 = soil_temperature_1 > extraTemp2 = soil_temperature_2 > extraHumid1 = soil_moisture_1 > extraHumid2 = soil_moisture_2 > > 3/ Si vous avez des sondes de température et hygrométrie *de sol*, ok pas > de problème. En revanche si vous avez des sondes de température extérieures > indiquant la température et l'hygrométrie de l'air ambiant, c'est curieux > que le nom récupéré soit "soil_xxx". > Mais comme je vous l'indiquais, sur Awekas, quand je récupère via > l'API les données envoyées par la base Bresser, les températures des sondes > extérieures sont dans les bons champs, en revanche les hygrométries sont > rentrées dans des hygrométries de sonde de sol.. > C'est très curieux, et dixit le SAV de Bresser France, je ne suis pas > le seul à avoir signalé la chose ! > Côté Bresser "teutons", la chose ne semble pas trop leur poser de > problème métaphysiques... A moins que la modification du firmware de la > base de la station ne soit pas une de leurs priorités ! > > *Rémy LAVABRE* > > > Le sam. 24 févr. 2024 à 10:54, sc.lep...@gmail.com <sc.lep...@gmail.com> > a écrit : > >> Hello Remy (... et bonjour en Français :) >> On va le faire en Français c'est plus simple : >> je récupère les data via interceptor en Wifi sur Weewx ... Toutes mes >> datas je les récupère correctement. >> la valeur inTemp est celle de la base ca ok . >> mais j'ai 2 sondes en plus et je voudrais également récupérer ces >> données (soilTemp1 et soilTemp2) et ma question était comment paramétrer >> le driver interceptor >> Sur le repo github ce n'est pas très clair... >> >> Mon site est ici : https://meteo-pontscorff.fr/ (il y a mes >> coordonnées mail) >> Merci ! >> Stéphane >> >> Le samedi 24 février 2024 à 05:49:39 UTC+1, Remy LAVABRE a écrit : >> >>> stephane hello, >>> I said something stupid to you previously. interceptor intercepts at the >>> wifi level and not as I thought at the 400 or 800 Mhz radio level... sorry! >>> >>> so normal that you have inTemp and barometer! :-) >>> >>> I too have a Bresser station and retrieve data automatically from Awekas >>> in the absence of a USB output. I have several exterior sensors and there >>> is a somewhat similar problem. the hygrometer values of the probes are >>> retrieved as hygrometer values of the floor probes while the temperatures >>> are retrieved as temperatures of external probes. >>> >>> I reported this anomaly to Bresser in France who already reported it >>> almost a year ago, knowing that I was not the only one to have reported it >>> to them. >>> I also reported the problem to Germany who basically told me it was >>> "normal" operation without explanation.... >>> >>> As I wrote a driver for weewx which retrieves data directly from Awekas >>> at regular intervals, I reverse the value fields myself... >>> >>> Le ven. 23 févr. 2024, 23:19, sc.lep...@gmail.com <sc.lep...@gmail.com> >>> a écrit : >>> >>>> Hello >>>> I use weewx with interceptor : >>>> >>>> Feb 23 23:09:01 meteo-Ubuntu weewx-BRESSER[63190] DEBUG >>>> user.interceptor: raw packet: {'dateTime': 1708726142, 'usUnits': 1, >>>> 'rain_total': 0.09, 'barometer': 29.99, 'temperature_out': 34.7, >>>> 'humidity_out': 90.0, 'wind_speed': 0.0, 'wind_gust': 0.0, 'wind_dir': >>>> 138.0, 'dewpoint': 32.0, 'temperature_in': 66.2, 'humidity_in': 57.0, >>>> 'uv': >>>> 0.0, 'solar_radiation': 0.0, 'soil_temperature_1': 66.2, >>>> 'soil_temperature_2': 70.8, 'soil_moisture_2': 60.0, 'rain': None} >>>> Feb 23 23:09:01 meteo-Ubuntu weewx-BRESSER[63190] DEBUG >>>> user.interceptor: mapped packet: {'dateTime': 1708726142, 'usUnits': 1, >>>> 'barometer': 29.99, 'outHumidity': 90.0, 'inHumidity': 57.0, 'outTemp': >>>> 34.7, 'inTemp': 66.2, 'windSpeed': 0.0, 'windGust': 0.0, 'windDir': 138.0, >>>> 'radiation': 0.0, 'dewpoint': 32.0, 'rain': None, 'UV': 0.0, 'soilTemp1': >>>> 66.2, 'soilTemp2': 70.8, 'soilMoist2': 60.0} >>>> >>>> I dont understand how to use : >>>> soilTemp1': 66.2, ' >>>> soilTemp2': 70.8, ' >>>> soil_moist1': 60.0, >>>> soil_moist2': 60.0, >>>> >>>> I've 2 temperatures probes >>>> >>>> Can someone explain me how to add this in weewx.conf ? >>>> >>>> in section : >>>> [[sensor_map_extensions]] >>>> ??? inTemp = temperature_1 >>>> ??? inHumidity = humidity_1 >>>> ??? outTemp = temperature_4 >>>> ??? outHumidity = humidity_4 >>>> >>>> >>>> Thanks a lot ;) >>>> >>>> Stephane >>>> >>>> -- >>>> >>> You received this message because you are subscribed to the Google >>>> Groups "weewx-user" group. >>>> To unsubscribe from this group and stop receiving emails from it, send >>>> an email to weewx-user+...@googlegroups.com. >>>> To view this discussion on the web visit >>>> https://groups.google.com/d/msgid/weewx-user/c851119a-b274-4ecd-99a3-605d2e393946n%40googlegroups.com >>>> >>>> <https://groups.google.com/d/msgid/weewx-user/c851119a-b274-4ecd-99a3-605d2e393946n%40googlegroups.com?utm_medium=email&utm_source=footer> >>>> . >>>> >>> -- >> You received this message because you are subscribed to the Google Groups >> "weewx-user" group. >> To unsubscribe from this group and stop receiving emails from it, send an >> email to weewx-user+...@googlegroups.com. >> > To view this discussion on the web visit >> https://groups.google.com/d/msgid/weewx-user/b81baf0d-7454-403b-86c3-5cd1305b6fcdn%40googlegroups.com >> >> <https://groups.google.com/d/msgid/weewx-user/b81baf0d-7454-403b-86c3-5cd1305b6fcdn%40googlegroups.com?utm_medium=email&utm_source=footer> >> . >> > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to weewx-user+unsubscr...@googlegroups.com. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/ddb3080b-9d5d-4fd8-ba2d-fc01adc0b59dn%40googlegroups.com.