stephane hello, I said something stupid to you previously. interceptor intercepts at the wifi level and not as I thought at the 400 or 800 Mhz radio level... sorry!
so normal that you have inTemp and barometer! :-) I too have a Bresser station and retrieve data automatically from Awekas in the absence of a USB output. I have several exterior sensors and there is a somewhat similar problem. the hygrometer values of the probes are retrieved as hygrometer values of the floor probes while the temperatures are retrieved as temperatures of external probes. I reported this anomaly to Bresser in France who already reported it almost a year ago, knowing that I was not the only one to have reported it to them. I also reported the problem to Germany who basically told me it was "normal" operation without explanation.... As I wrote a driver for weewx which retrieves data directly from Awekas at regular intervals, I reverse the value fields myself... Le ven. 23 févr. 2024, 23:19, sc.lep...@gmail.com <sc.leprov...@gmail.com> a écrit : > Hello > I use weewx with interceptor : > > Feb 23 23:09:01 meteo-Ubuntu weewx-BRESSER[63190] DEBUG user.interceptor: > raw packet: {'dateTime': 1708726142, 'usUnits': 1, 'rain_total': 0.09, > 'barometer': 29.99, 'temperature_out': 34.7, 'humidity_out': 90.0, > 'wind_speed': 0.0, 'wind_gust': 0.0, 'wind_dir': 138.0, 'dewpoint': 32.0, > 'temperature_in': 66.2, 'humidity_in': 57.0, 'uv': 0.0, 'solar_radiation': > 0.0, 'soil_temperature_1': 66.2, 'soil_temperature_2': 70.8, > 'soil_moisture_2': 60.0, 'rain': None} > Feb 23 23:09:01 meteo-Ubuntu weewx-BRESSER[63190] DEBUG user.interceptor: > mapped packet: {'dateTime': 1708726142, 'usUnits': 1, 'barometer': 29.99, > 'outHumidity': 90.0, 'inHumidity': 57.0, 'outTemp': 34.7, 'inTemp': 66.2, > 'windSpeed': 0.0, 'windGust': 0.0, 'windDir': 138.0, 'radiation': 0.0, > 'dewpoint': 32.0, 'rain': None, 'UV': 0.0, 'soilTemp1': 66.2, 'soilTemp2': > 70.8, 'soilMoist2': 60.0} > > I dont understand how to use : > soilTemp1': 66.2, ' > soilTemp2': 70.8, ' > soil_moist1': 60.0, > soil_moist2': 60.0, > > I've 2 temperatures probes > > Can someone explain me how to add this in weewx.conf ? > > in section : > [[sensor_map_extensions]] > ??? inTemp = temperature_1 > ??? inHumidity = humidity_1 > ??? outTemp = temperature_4 > ??? outHumidity = humidity_4 > > > Thanks a lot ;) > > Stephane > > -- > You received this message because you are subscribed to the Google Groups > "weewx-user" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to weewx-user+unsubscr...@googlegroups.com. > To view this discussion on the web visit > https://groups.google.com/d/msgid/weewx-user/c851119a-b274-4ecd-99a3-605d2e393946n%40googlegroups.com > <https://groups.google.com/d/msgid/weewx-user/c851119a-b274-4ecd-99a3-605d2e393946n%40googlegroups.com?utm_medium=email&utm_source=footer> > . > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to weewx-user+unsubscr...@googlegroups.com. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/CADhm9Yf4z%3DAm12NEJYBFe6vDQbAUWz-H74mNWnenaQGQ5SdQOg%40mail.gmail.com.