Well that change helped and shows MQTTSubscribe reading the values but now it says can't convert degree_C to percent as per the following for rtd_temperature (same for tmp117_temperature) Also what should I do when copying sections of weewx.conf to make it easier to read?
Mar 2 17:56:03 pi34 weewx[10834] DEBUG user.MQTTSubscribe: (Service) MessageCallbackProvider data-> incoming topic: rtd_temperature, QOS: 0, retain: 0, payload: b'20.39' Mar 2 17:56:03 pi34 weewx[10834] DEBUG weewx.units: Unable to convert from degree_C to percent Mar 2 17:56:03 pi34 weewx[10834] ERROR user.MQTTSubscribe: (Service) MessageCallbackProvider on_message_individual failed with <class 'KeyError'> and reason 'percent'. Mar 2 17:56:03 pi34 weewx[10834] ERROR user.MQTTSubscribe: (Service) **** MessageCallbackProvider Ignoring topic=rtd_temperature and payload=b'20.39' Mar 2 17:56:03 pi34 weewx[10834] ERROR user.MQTTSubscribe: (Service) **** MessageCallbackProvider Traceback (most recent call last):#012 File "/home/weewx/bin/user/MQTTSubscribe.py", line 1527, in _on_message_individual#012 (fieldname, value) = self._update_data(fields, fields_conversion_func, key, payload_str, unit_system)#012 File "/home/weewx/bin/user/MQTTSubscribe.py", line 1264, in _update_data#012 (value, new_units, new_group) = weewx.units.convert((value, fields[orig_name]['units'], None), to_units) # match signature pylint: disable=unused-variable#012 File "/home/weewx/bin/weewx/units.py", line 1454, in convert#012 conversion_func = conversionDict[val_t[1]][target_unit]#012KeyError: 'percent' On Thursday, March 2, 2023 at 5:21:16 PM UTC-7 vince wrote: > In that case should [[[topic/rtd_temperature]]] be just > [[[rtd_temperature]]] perhaps ??? > > It's a bit hard to decipher with such a cryptic description and > unfortunately google ate whatever formatting you entered on your cut+paste, > so your original post is very hard to read as a result. > > Give it a try. It's already not working so you can't make anything worse. > > On Thursday, March 2, 2023 at 3:21:42 PM UTC-8 lloyd...@gmail.com wrote: > >> without the xargs >> >> rtd_temperature 20.70 >> tmp117_temperature 18.33 >> >> >> On Thursday, March 2, 2023 at 4:12:46 PM UTC-7 vince wrote: >> >>> How about you just show the mosquitto_sub results without the xargs pipe >>> please... >>> >>> -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to weewx-user+unsubscr...@googlegroups.com. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/788ab4e5-053a-4511-811b-a0a554e9b1e8n%40googlegroups.com.