Not getting extraTemp1 nor extraTemp2 that are being sent via MQTT. Any help would be appreciated.
I know the data is getting to the mosquitto broker. This is the setup on weewx.conf. [MQTTSubscribeService] # This section is for the MQTTSubscribe service. # Turn the service on and off. # Default is: true # Only used by the service. enable = true # The MQTT server. # Default is localhost. host = 192.168.1.166 # The port to connect to. # Default is 1883. port = 1883 # Maximum period in seconds allowed between communications with the broker. # Default is 60. keepalive = 120 # username for broker authentication. # Default is None. Username = ODT # password for broker authentication. # Default is None. Password = ?????? # The binding, loop or archive. # Default is: loop # Only used by the service. binding = loop # The message handler to use [[message_callback]] # The format of the MQTT payload. # Currently support: individual, json, keyword # Must be specified. type = individual # The topics to subscribe to. [[topics]] # Units for MQTT payloads without unit value. # Valid values: US, METRIC, METRICWX # Default is: US unit_system = METRIC # When true, the fieldname is set to the topic and therefore [[[[fieldname]]]] cannot be used. # This allows the [[[[fieldname]]]] configuration to be specified directly under the [[[topic]]]. # Default is False. use_topic_as_fieldname = True # The first topic to subscribe to. [[[topic/rtd_temperature]]] # The WeeWX name. # Default is the name from MQTT. name = extraTemp1 # True if the incoming data should not be processed into WeeWX. # Valid values: True, False # Default is False ignore = False # True if the incoming data is cumulative. # Valid values: True, False # Default is False contains_total = False # The conversion type necessary for WeeWX compatibility # Valid values: bool, float, int, none # Default is float conversion_type = float # The units of the incoming data. # Useful if this field's units differ from the topic's unit_system's units. # Valid values: see, http://www.weewx.com/docs/customizing.htm#units # Default is not set units = degree_C [[[topic/tmp117_temperature]]] # The WeeWX name. # Default is the name from MQTT. name = extraTemp2 # True if the incoming data should not be processed into WeeWX. # Valid values: True, False # Default is False ignore = False # True if the incoming data is cumulative. # Valid values: True, False # Default is False contains_total = False # The conversion type necessary for WeeWX compatibility # Valid values: bool, float, int, none # Default is float conversion_type = float # The units of the incoming data. # Useful if this field's units differ from the topic's unit_system's units. # Valid values: see, http://www.weewx.com/docs/customizing.htm#units # Default is not set units = degree_C When I run debug = 1 I get this but no extraTemp1 or 2 Mar 2 15:26:15 pi34 weewx[4895] DEBUG user.MQTTSubscribe: (Service) data-> final packet is 2023-03-02 15:26:16 MST (1677795976): 'dateTime': '1677795976', 'inHumidity': '22.568543063381135', 'inTemp': '17.212429480347783', 'rainRate': '0', 'txBatteryStatus': '0', 'usUnits': '17', 'windDir': '265.8379446640316', 'windSpeed': '0.0' When I run debug=0, I get at weewx restart Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) Version is 2.2.2 Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) Log level: 0 Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) Log debug setting: 0 Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) Log console: False Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) Log file: None Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) 'use_topic_as_fieldname' option is no longer needed and can be removed. Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) message_callback_provider_name is user.MQTTSubscribe.MessageCallbackProvider Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) clientid is MQTTSubscribe-5972 Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) client_session is True Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) host is 192.168.1.166 Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) port is 1883 Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) keepalive is 120 Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) username is ODT Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) min_delay is 1 Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) max_delay is 120 Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) password is set Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) Archive topic is None Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) binding is loop Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) Waiting for MQTT connection. Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) Connected with result code 0 Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) Connected flags {'session present': 0} Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) Subscribing to topic/rtd_temperature has a mid 1 and rc 0 Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) Subscribing to topic/tmp117_temperature has a mid 2 and rc 0 Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) Subscribed to mid: 1 is size 1 has a QOS of 0 Mar 2 15:31:13 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) Subscribed to mid: 2 is size 1 has a QOS of 0 Mar 2 15:31:14 pi34 weewx[7610] INFO user.MQTTSubscribe: (Service) MQTT initialization complete. My setup is a ESP32 reading a RTD100 and a TMP117 temperature, sending the data every 15 seconds via MQTT to the Pi 3 B+ running Bullseye and WeeWX version 4.10.2. WeeWX is running lheijst’s github weewx-rtldavis software to read the Davis Vantage Pro2 ISS and wjcarpenter’s gitlab bme280wx.git as a service to read the BME280 for indoor temp and barometer. mosquitto broker version 2.0.11 at the Pi. mosquitto is an MQTT v5.0/v3.1.1/v3.1 broker. When I run mosquitto_sub -h 192.168.1.166 -t + -v -u ??? -P ???? | xargs -d$'\n' -L1 bash -c 'date "+%Y-%m-%d %T.%3N $0"' the ? are to not give out my user and password info and the pipe to xargs is to add date and time I get the data sent from the ESP32 2023-03-02 13:04:20.439 rtd_temperature 20.29 2023-03-02 13:04:20.455 tmp117_temperature 18.09 -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/a68e7c59-623b-4b2b-a2ab-eebaeae76ff7n%40googlegroups.com.