Thanks for sharing Jed! One thing that makes me wondering is how the Nickel mesh in fig.3 is connected. >From the text I understand that either Pd or Ni is used in the experiments (likely as cathodes). That would mean D2 + Pd or H2 + Ni experiments were performed. Which if the two resulted in surplus of heat? Swapping HV polarity would mean either electrons or D+/H+ ions reach the targeted cathode. Is this a correct interpretation?
- [Vo]:Mizuno paper poster Jed Rothwell
- Re: [Vo]:Mizuno paper poster Teslaalset
- Re: [Vo]:Mizuno paper poster Jed Rothwell