On 10/12/2024 13:42, Eugene Grayver wrote:
Hi,

I just noticed that the calibration tables are disabled/ignored when external LO is used.  Why is that?  I understand that the automatic calibration utilities will not work (over frequency). However, we are generating those tables ourselves, and expect UHD to use them.  Now I have to hack my own code to duplicate the calibration functionality and 'manually' call set_dc_..., etc functions.

Thanks.

I guess because the CAL* utilities run the chip in local-LO mode, and the IQ and DC cals are only valid for it.

Now, your point about producing those tables yourself is actually a good point, and I think this constitutes a
  feature request...

_______________________________________________
USRP-users mailing list -- usrp-users@lists.ettus.com
To unsubscribe send an email to usrp-users-le...@lists.ettus.com

Reply via email to