Hi everyone, I'm glad to report this can indeed be accomplished at full
samples rate on each channel with stock UHD 4.6.0.0, with code similar to
what's documented here (I did it in python):

https://kb.ettus.com/Using_the_RFNoC_Replay_Block_in_UHD_4 
 
One just does the same setup on two replay block channels. The sample rates
can even be different.

Thanks Maximilian, Lars and everyone
----

From: Chapman, Christian - 0664 - MITLL <christian.chap...@ll.mit.edu> 
Sent: Thursday, April 18, 2024 5:08 PM
To: usrp-users@lists.ettus.com
Subject: [EXT] [USRP-users] Transmitting on both X300 channels without
streaming samples

Hi, I'm interested in using an X300 to repeat several 100 ms of >100 MHz
samples, a different signal on both channels, and my host computer can't
stream samples into the X300 continuously.
It would seem the RFNoC replay block could serve this need, but according to
a thread from Thomas Harder on a very similar question[1] some firmware
change is required. 
Thomas seems to have settled on the approach I can't use: his samples are
streamed continuously via 10G Ethernet.
If I understand properly, Rob Kossler's txarb block can serve this need, but
I can't find it published it anywhere. Do I have to recreate something
similar to do what I need?
More broadly, has anyone done this and/or have simpler solutions appeared in
the last few years?

[1]: transmitting on two channels with replay block, msg09472

Thank you,
Christian

Attachment: smime.p7s
Description: S/MIME cryptographic signature

_______________________________________________
USRP-users mailing list -- usrp-users@lists.ettus.com
To unsubscribe send an email to usrp-users-le...@lists.ettus.com

Reply via email to