I was waiting to confirm measurements:
* I confirm libuhd 3.15 running the X310 will NOT display the same effect 
* I confirm libuhd 4 DOES display the same effect on the B210.

I can provide the charts which I did not upload on the gnss-sdr github issue
as demonstration of these measurements.

Thanks, JM

--
JM Friedt, FEMTO-ST Time & Frequency, 26 rue de l'Epitaphe, 25000 Besancon, 
France

November 6, 2020 7:18 PM, "Marcus D Leech" <patchvonbr...@gmail.com> wrote:

> Do you see the same thing on other platforms? What about newer/older UHD 
> versions?
> 
> Sent from my iPhone
> 
>> On Nov 6, 2020, at 5:29 AM, JM Friedt via USRP-users 
>> <usrp-users@lists.ettus.com> wrote:
>> 
>> While analyzing GPS timing capabilities of gnss-sdr as described at
>> https://github.com/gnss-sdr/gnss-sdr/issues/442
>> we have become convinced that the B210 transferring data using libuhd 3.15
>> drops one samples every 2^32 (i.e one sample every 4294967296). This 
>> conclusion
>> was reached by changing the sampling rate and observing that the time shift 
>> in
>> the GPS timing capability was jumping by one sample period every 4294967296
>> acquisitions (i.e. 36 minutes at 2 MS/s or 57 minutes at 1.25 MS/s). This 
>> issue
>> is NOT observed with an X310 streaming data to the same libuhd source.
>> We have no idea how to address or solve the problem, but any hint at how to 
>> correct
>> the issue would be welcome.
>> 
>> Thank you, Jean-Michel
>> 
>> [1] running on a Raspberry Pi4 with a 64-bit kernel and 64-bit 
>> libraries/toolchain compiled
>> with Buildroot
>> 
>> --
>> JM Friedt, FEMTO-ST Time & Frequency, 26 rue de l'Epitaphe, 25000 Besancon, 
>> France
>> 
>> _______________________________________________
>> USRP-users mailing list
>> USRP-users@lists.ettus.com
>> http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com

_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com