The X310 does not support White Rabbit or IEEE 1588.

The N310/N320 have only been validated using a White Rabbit Master such as
this one: https://sevensols.es/index.php/index/timing-products/wr-len/
A simple PTP Master will almost certainly not work with the WR FPGA
bitstream.


On Thu, Oct 29, 2020 at 1:56 AM Bruckmeyer, Heiko via USRP-users <
usrp-users@lists.ettus.com> wrote:

> Hello,
>
>
>
> I have a question regarding the use of the simple synchronization protocol
> IEEE1588 Precision-Time-Protocol.
>
> I want to use Ettus USRP N3xx. I know that they support the White Rabbit
> protocol for synchronizing. PTP is a part of the White Rabbit. So is it
> possible to use a simple PTP Master and synchronize the USRP to it or do I
> need a White Rabbit Master?
>
> I know that the use of simple PTP will degrade the synchronization
> accuracy.
>
>
>
> Does the USRP X3xx also support White Rabbit or IEEE1588 PTP?
>
>
>
> Thanks and best regards,
>
> H. Bruckmeyer
>
>
>
>
>
>
>
>
> _______________________________________________
> USRP-users mailing list
> USRP-users@lists.ettus.com
> http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com
>
_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com

Reply via email to