On 08/23/2020 08:28 AM, Prasad wrote:
Dear Marcus,
Verified the code couple of time even tested bypassing USRP and it
works fine.
So, suspecting any time_spec either in RX or TX missing in the code?
Regards,
Prasad.
What is your sample rate? Over what time scales do you see an apparent
"time slip"?
*From:*Marcus D. Leech [mailto:patchvonbr...@gmail.com]
*Sent:* Sunday, August 23, 2020 6:56 AM
*To:* kp...@trilcomm.com; usrp-users@lists.ettus.com
*Subject:* Re: [USRP-users] USRP B210: getting RX samples with
gradually increase delay
On 08/22/2020 09:08 PM, kp...@trilcomm.com <mailto:kp...@trilcomm.com>
wrote:
Yes relative delay between samples in buffer.
While detecting SYNC signal of 5G periodically, it detects
gradually increased delay from its expected position.
It means expected to receive at 2280 position of buffer but its
keep detecting away from expected position,
2281,2282,2284,........ and so on.
Thanks,
Prasad.
My guess is that you have an off-by-one error in your
buffer-harvesting code. This has nothing to do with the device.
_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com