Thank you Brian! It runs fine :)

El lun., 11 may. 2020 a las 17:08, Brian Padalino (<bpadal...@gmail.com>)
escribió:

> On Mon, May 11, 2020 at 6:20 AM Carlos Alberto Ruiz Naranjo via USRP-users
> <usrp-users@lists.ettus.com> wrote:
>
>> Hello,
>>
>> I'm using the USRP X310 with CBX-120. I set the radio sample rate to
>> 184.32 MHz but I have the following message:
>>
>> [WARNING] [X300 RADIO] Requesting invalid sampling rate from device:
>> 184.32 MHz. Actual rate is: 200 MHz.
>>
>> Isn't it possible to set it to that sample rate?
>>
>
> You need to set the master_clock_rate in the arguments of the USRP to be
> 184.32MHz.
>
>   https://files.ettus.com/manual/page_configuration.html
>
> Brian
>
_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com