On 01/30/2020 01:35 PM, Richard Bell via USRP-users wrote:
Hello,
I am trying to collect serveral data sets through USRP X300's. Assume
each collection is 1000 samples long and is initiated by a user typing
a button on the keyboard. Each time the user hits a key 1000 samples
are collected and stored to a file. The time between each collect is
defined by the user hitting the key.
I need to make sure the USRPs are not loosing carrier lock between
these collections. I want the USRPs to stay locked to whatever center
frequency is set and sit there for the length of the time the user
wants to collect data sets. What is the best way to ensure this?
For example, if I use GNU Radio and head blocks feeding into file
sinks with calls to tb.start and tb.stop, does the call to tb.stop
cause the USRP to forget the carrier it was locked to and start over
again on the next call to tb.start? Can I call tb.start multiple times
without a call to tb.stop?
Thank for any help you can provide.
I think this will likely work, although I think it depends on how much
"device init" is done on flow-graph start. I think a lot of it is done when
the device is instantiated, and whatever happens at FG start is
device-dependent.
You'll have to test this in your environment.
You might also chose another architecture for your software to remove
the possibility of device re-init.
You can for example just stream forever, and only pay attention to the
samples you want to pay attention to.