Hi,

I am trying to synchronize two USRP N210 devices, one for TX and one for RX.
I've followed all of the instructions in the "Synchronizing the Device Time"
and "Align CORDICs in the DSP" seconds of the manual
(https://files.ettus.com/manual/page_sync.html); however, I'm still not
getting complete success.  

 

I can synchronize the two devices only if I use a center frequency of 0 Hz,
as shown in the attached cf_0e6.jpg.  If I use a center frequency of 10e6 Hz
for both TX and RX then there is a phase change between program runs, as
shown in the attached cf_10e6.jpg.  Each screenshot shows five recordings
spaced 20 seconds apart for two runs of the program.    

 

Should these results be expected?  

-          If so, can someone explain why there is a random phase offset
when using a non-zero center frequency. 

-          If not, what am I doing wrong?  I can share my code if that
helps. 

 

I also tried following the instructions in the "Align Los in the front-end
(SBX, UBX)", but that didn't help.  I didn't think it would help since I'm
using LFTX and LFRX boards.  

 

My hardware setup:

Transmitter: N210 with a LFTX and GPSDO

Receiver: N210 with a LFRX and GPSDO

 

Any help/feedback would be greatly appreciated,

Thanks!

-Ben