Mark,

To follow up on this topic.

I understand what you are saying about the max sample rate of being 25Msps, and 
being on the edge.  However, I have never seen the problem occur with a N210 on 
my same setup.

Mark

From: Mark Koenig <mark.koe...@iubelttechnologies.com>
Date: Friday, June 7, 2019 at 12:35 PM
To: Jason Matusiak <ja...@gardettoengineering.com>, Neel Pandeya 
<neel.pand...@ettus.com>
Subject: Re: [USRP-users] UHD Comms Error

No, I believe that was introduced in uhd 3.10 and higher.  I am currently 
running 3.9.7, but have seen RFNoC errors using 3.10.002.

From: Jason Matusiak <ja...@gardettoengineering.com>
Date: Friday, June 7, 2019 at 12:33 PM
To: Neel Pandeya <neel.pand...@ettus.com>, Mark Koenig 
<mark.koe...@iubelttechnologies.com>
Subject: Re: [USRP-users] UHD Comms Error


Is this an RFNoC load?

________________________________
From: USRP-users <usrp-users-boun...@lists.ettus.com> on behalf of Mark Koenig 
via USRP-users <usrp-users@lists.ettus.com>
Sent: Friday, June 7, 2019 12:29 PM
To: Neel Pandeya
Cc: usrp-users@lists.ettus.com
Subject: Re: [USRP-users] UHD Comms Error


I am using a thunderbolt 3 interface, but only using it at 1Gig, standard 1500 
MTU.  I am running at a sample rate of 25Msps.



Mark



From: Neel Pandeya <neel.pand...@ettus.com>
Date: Thursday, June 6, 2019 at 2:00 PM
To: Mark Koenig <mark.koe...@iubelttechnologies.com>
Cc: "usrp-users@lists.ettus.com" <usrp-users@lists.ettus.com>
Subject: Re: [USRP-users] UHD Comms Error



Hello Mark:



This may indicate a hardware problem.  What is specifically eliciting the 
error?  Does it occur with every time that there is a tune request?  Are you 
running your own program, or one the example programs, such as 
"rx_samples_to_file"?  Could you please try upgrading to UHD 3.14.0.0, and 
re-running your test, and let me know your results?



--Neel Pandeya







On Thu, 6 Jun 2019 at 12:47, Mark Koenig via USRP-users 
<usrp-users@lists.ettus.com<mailto:usrp-users@lists.ettus.com>> wrote:

Please help, with the error I am seeing.



I am currently using an X310 with a UBX160 daughtercard and I get the error 
below when changing the frequency parameters of the radio.



RuntimeError: EnvironmentError: IOError: Radio ctrl (A) packet parse error - 
AssertionError: packet_info.packet_count == (seq_to_ack & 0xfff)

  in uint64_t radio_ctrl_core_3000_impl::wait_for_ack(bool)





I am currently running UHD 3.9.7, but have also seen a similar error with 3.10.2



Thanks



Mark

_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com<mailto:USRP-users@lists.ettus.com>
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com
_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com

Reply via email to